MedPhysBench: A Benchmark for Evaluating Language Models on Medical Physics Calculations and Error Detection
Omar Nusrat
Key points
From the paper's conclusion- We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.
Abstract
Medical physicists turn a prescription into a delivered dose and check one another's calculations, because one error in a beam calibration or a monitor-unit (MU) calculation can affect every patient treated with it. MedPhysBench has ten seeded generators of calculation items in radiation therapy, diagnostic imaging, nuclear medicine and radiation protection, up to clinical tasks such as a TG-51 calibration worksheet. Reference answers come from code implementing the governing protocols, and a grader converts units and applies tolerance bands. From the same inputs, separate checking items test error detection, showing a colleague's worksheet or only the colleague's result, half correct and half with one planted error. On a held-out test split of 1,200 items (half for two models), 12 models scored 33.3 to 100.0% on calculation. Of the nine answers graded incorrect for the four best (99.3-100.0%), five contained model errors and four followed NCRP Report 151 on points our items misstate or leave open. Below them, most models did worst on level-3 clinical tasks, and Claude Sonnet 5.5 omitted the inverse-square correction in 19 of 20 isocentric MU items. Five models detected at least 96.7% of mostly large planted errors with at most 4% false alarms; for four of the other seven, checking only the result raised false alarms significantly. In an exploratory targeted test with 20 public cases of an omitted inverse-square correction, the three best models tested caught it in every worksheet, and three weaker models accepted 16 to 18 of 20 planted worksheets, one of them while applying the correction in most of its own calculations. Claude Opus 5.5 accepted 6 of 20 wrong results, although it applied the correction in all 20 of its own. We report the effect of two problems in our shielding items, found after the runs, and release the code, per-item outcomes and targeted-test responses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluationEuropean Radiology · 2026
- Clinical selectivity and failure modes of automated chest radiograph report evaluation metrics: a cross-dataset analysis of ReXErr-v1 and RadEvalXmedRxiv · 2026
- Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image EvidencearXiv · 2026
- Performance of Frontier Large Language Models on an FRCR Part 1-Style Examination: A Comparative Study of Physics and Anatomy Modules.Academic radiology · 2026
- Diagnostic performance of large language models for discrepancy detection in non-English resident-authored abdominal CT and MRI reports: a Turkish-language evaluation.Abdominal radiology (New York) · 2026
- Benchmarking Open-Source Large Language Models for Breast Ultrasound Report Processing: A Multicenter Study.Diagnostics (Basel, Switzerland) · 2026