Dual-Band Mid-Infrared Imaging for Measurement of Fuel Concentration and Temperature in a Supersonic Cavity
Loren C. Hahn, Erik L. Braun, Brendan J. McGann, Katherine C. Opacich, Timothy M. Ombrello
Key points
From the paper's conclusion- A dual-band mid-infrared absorption imaging method is demonstrated for spatially resolved measurement of ethylene concentration and temperature in a Mach-2 cavity flow.
Abstract
A dual-band mid-infrared absorption imaging method is demonstrated for spatially resolved measurement of ethylene concentration and temperature in a Mach-2 cavity flow. The method used narrowband filters selected to exploit the differing in-band temperature sensitivities of ethylene absorption, together with a broadband infrared source and high-frame-rate mid-wave infrared camera. Temperature-dependent, filter-weighted absorption cross-sections were used to measure two-dimensional ethylene number density and temperature fields. Measurements were obtained for cavity, curtain, and discrete fuel-injection configurations, including cases with the leading edge of a quasi-steady shock near the cavity. Cavity equivalence ratio measurements agreed well with independent extractive measurements and reproduced trends previously observed using hyperspectral imaging. A complementary single-band implementation using a temperature-independent filter provided instantaneous ethylene concentration fields at 100 Hz and revealed intermittent reductions in cavity equivalence ratio associated with plume deflection by the shock train leading edge. The dual-band approach provides quantitative full-field measurements with substantially simpler spectral instrumentation than hyperspectral imaging while retaining flexibility for time-resolved flow measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-speed mass flux measurements using mid-infrared electro-optic dual-comb spectroscopy.Applied optics · 2026
- Vibrational temperature measurement of diatomic nitrogen using femtosecond/picosecond coherent anti-Stokes Raman scattering in the ONR-UTA arc-jet facilityExperiments in Fluids · 2026
- Dual-band scanned-wavelength infrared laser-induced fluorescence of CO with time-domain modeling for 1 kHz thermometry.Optics express · 2026
- Dual-comb spectroscopy for spatially resolved hydrogen combustion diagnostics over a wide temperature range.Optics express · 2026
- Integration log rotational-state distribution thermometry for multi-component gas temperature measurement using dual-comb spectroscopyJournal of the Optical Society of America B · 2025
- Dual-comb spectroscopy for in-situ temperature measurements of gas-filled hollow-core fibers.Optics letters · 2026