Dual-comb spectroscopy for spatially resolved hydrogen combustion diagnostics over a wide temperature range.
Meng-Zhe Lian, Wei-Fan Hu, Yu-Xuan Cao, Ming-Ming Gu, Yan Tan, Hao-Wei Liu, You Pang, Lei Hou,
Hefei National Research Center for Physical Sciences at the Microscale and School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China. · School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Key points
From the paper's conclusion- We employ nonlinear frequency conversion to shift the spectral range of a near-infrared DCS system from the commonly used 1.4 µm region to the optimized 1.34 µm window.
Abstract
Dual-comb spectroscopy (DCS) provides exceptional broadband precision for non-intrusive combustion diagnostics. In this work, we present a detailed quantitative reconstruction for laminar hydrogen-air flames across a wide range of thermal conditions, a key regime for advancing clean energy technologies. We employ nonlinear frequency conversion to shift the spectral range of a near-infrared DCS system from the commonly used 1.4 µm region to the optimized 1.34 µm window. This spectral selection significantly reduces environmental interferences and ensures the consistent availability of temperature-sensitive H2O absorption features across a wide temperature range. To address the inherent spatial non-uniformity in laminar hydrogen flames, we implement a gradient-aware inversion strategy based on a Boltzmann sigmoidal profile. Coupled with a high-temperature H2O spectral database, this approach allows the parametric reconstruction of spatial profiles of temperature and H2O mole fraction from single line-of-sight absorption spectra, measured across varying equivalence ratios. The retrieved temperature profiles, within the validated temperature range of the spectroscopic database, show agreement with established reference data within an uncertainty of 50 K. This work establishes a robust DCS framework for hydrogen combustion diagnostics and provides a quantitative reconstruction that will support the development and validation of kinetic models for clean energy applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-comb spectroscopy for the characterization of laboratory flamesSensors and Actuators B Chemical · 2026
- Dual-comb spectroscopy for in-situ temperature measurements of gas-filled hollow-core fibers.Optics letters · 2026
- Vacuum ultraviolet dual-comb spectroscopy.Nature communications · 2026
- Dual-band scanned-wavelength infrared laser-induced fluorescence of CO with time-domain modeling for 1 kHz thermometry.Optics express · 2026
- Integration log rotational-state distribution thermometry for multi-component gas temperature measurement using dual-comb spectroscopyJournal of the Optical Society of America B · 2025
- Dual-comb photoacoustic and photothermal spectroscopy: A comprehensive reviewPhotoacoustics · 2025