From the paper's conclusion- We evaluated how radial undersampling and reconstruction strategy affect CEP $T_2^*$ fidelity in a fully synthetic setting.
Abstract
The lumbar cartilage endplate (CEP) is a short-$T_2^*$ structure whose composition has been linked to disc health. Ultrashort-echo-time (UTE) MRI enables direct CEP visualization, but acceleration and reconstruction may alter quantitative $T_2^*$ even when image quality improves. We evaluated how radial undersampling and reconstruction strategy affect CEP $T_2^*$ fidelity in a fully synthetic setting. A 96 x 96 sagittal lumbar phantom with five CEP levels (ground-truth $T_2^*$: 24, 22, 20, 18, and 16 ms) was simulated with six UTE echoes, eight receive coils, and radial sampling. Acceleration factors $R=1,2,4,6,8$ used 302, 151, 76, 50, and 38 spokes, respectively. Reconstructions were CG-SENSE, joint multi-echo FISTA, and direct model-based estimation from k-space. Twenty independent complex-noise realizations were evaluated per acceleration. Direct model-map RMSE increased from 0.172 ms at $R=1$ to 0.800 ms at $R=4$, 1.472 ms at $R=6$, and 2.256 ms at $R=8$. At $R=4$, joint-FISTA had lower image NRMSE than the direct model (0.132 vs. 0.203), while the direct map had lower level-wise $T_2^*$ RMSE than CG-SENSE and joint-FISTA ROI fits (0.800 vs. 1.448 and 1.288 ms; estimators differed). At $R=8$, CG-SENSE ROI fitting had the lowest $T_2^*$ RMSE (1.501 ms), whereas the direct model showed systematic underestimation (bias, -2.136 ms; CCC, 0.723). Image fidelity and quantitative biomarker fidelity therefore diverged under radial acceleration. In this synthetic framework, $R=4$ was a promising operating point for direct CEP $T_2^*$ mapping, whereas $R=8$ produced substantial bias and spatial instability. Scanner, phantom, and in vivo validation are required before clinical translation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of a 2-Minute Multi-Echo UTE Acquisition for Simultaneous CT-Like Bone-Weighted Imaging and Quantitative T2* Mapping of Short-T2 TissuemedRxiv · 2026
- Quantitative characterization of spatial frequency-dependent effects of conjugate gradient reconstruction in relation to k-space fill ratio in non-contrast-enhanced ultra-short echo time brain magnetic resonance angiography.Magnetic resonance imaging · 2026
- Quantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank ReconstructionNMR in Biomedicine · 2026
- Short echo time first-echo images of T2* mapping for detecting structural sacroiliac joint lesions in axial spondyloarthritis: a CT-referenced study.Frontiers in immunology · 2026
- Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRIarXiv · 2026
- Joint reconstruction of multi-contrast relaxation-diffusion imaging.bioRxiv : the preprint server for biology · 2026