End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI
Lukas T. Rotkopf, Marco Schlimbach, Kevin Kr\"{o}ninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe
Key points
From the paper's conclusion- We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation.
Abstract
Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exploring UNet-based models for prostate lesion segmentation from multi-sequence MRI (T2W, ADC, DWI)World Wide Web · 2025
- Resource optimized neural architecture search for automated 3D prostate cancer segmentation from diffusion weighted MRI using weight sharing U-Net frameworkDiscover Artificial Intelligence · 2026
- Destructive augmentations for prostate lesion segmentation on heterogeneous biparametric MRI dataarXiv · 2026
- Report-Guided Semi-Supervised Learning for Scalable Prostate Cancer Detection on Biparametric MRI: Multicenter Prospective Validation and Multimodal IntegrationmedRxiv · 2026
- Diagnostic assessment of artificial intelligence reconstruction on accelerated prostate MRI: a retrospective, paired, multi-reader multi-case studyEuropean Radiology · 2026
- Semi-supervised learning in prostate MRI tumor detection approaches fully supervised performance on external validationEuropean Radiology · 2026