Diagnostic assessment of artificial intelligence reconstruction on accelerated prostate MRI: a retrospective, paired, multi-reader multi-case study
Quintin van Lohuizen, Stefan J. Fransen, George Yiasemis, Jasper J. Twilt, Christian Roest, Yuki Arita, Jacob Borstlap, Jurgen J. Fütterer,
University Medical Center Groningen · The Netherlands Cancer Institute
Key points
From the paper's conclusion- Overall visual quality at R = 6 remained comparable to R = 1 (2.81 at R6 vs.
Abstract
OBJECTIVES: To determine whether AI-reconstructed prostate MRI at reduced acquisition times maintains prostate cancer (PCa) detection performance comparable to conventional scans. MATERIALS AND METHODS: This multicenter, retrospective, consecutive-cohort study included 120 multi-coil T2-weighted prostate MRI scans from the University Medical Center Groningen (UMCG) and 312 publicly available scans from New York University (NYU). An AI model trained on the NYU data was tested on retrospectively undersampled UMCG scans at acceleration factors R = 3 and R = 6 (i.e., data reduction in k-space). Eight experienced radiologists participated in a multi-reader multi-case PCa detection study. Diagnostic performance was assessed using the area under the receiver operating characteristic curve (AUROC). Histopathology and PI-RADS ≤ 2 findings served as reference standards. Multiple image quality metrics were subjectively evaluated using a 4-point Likert scale. RESULTS: No statistically significant reduction in PCa detection was observed at an MRI acceleration up to R = 6 (p = 0.08). AUROC values were 0.86 (95% CI: 0.74-0.90) for R = 1, 0.82 (0.72-0.88) for R = 3, and 0.80 (0.70-0.86) for R = 6. Compared to R = 1, R = 3 scans were rated by radiologists to have significantly improved sharpness (+0.2, p < 0.05) and lower noise (+0.1, p < 0.05). Overall visual quality at R = 6 remained comparable to R = 1 (2.81 at R6 vs. 2.74 at R1). CONCLUSION: AI-driven reconstruction enabled a sixfold acceleration of T2-weighted prostate MRI (0:33-1:27 min) without a statistically significant reduction in PCa detection, while preserving perceived image quality. However, the decreasing diagnostic performance at higher accelerations warrants further prospective evaluation. KEY POINTS: Question This study investigated whether deep learning reconstruction enables three- to sixfold acceleration without reducing radiologists' detection of clinically significant prostate cancer. Findings In a multi-reader multi-case study with eight radiologists, three- and sixfold acceleration showed no significant change in area under the receiver operating characteristic curve. Clinical relevance Deep learning reconstruction shortened T2-weighted acquisition times at sixfold acceleration while preserving perceived image quality and diagnostic performance across acceleration factors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence in Prostate MRI : Addressing Current Limitations Through Emerging TechnologiesJournal of Magnetic Resonance Imaging · 2025
- Concurrent AI-human interaction in prostate cancer MRI interpretation: More hype than help?European Radiology Experimental · 2026
- Automated MRI system for clinically significant prostate cancer detection development validation and real-world implementationNature Communications · 2025
- AI-Assisted Interpretation of Prostate MRI: A Narrative Review.Journal of computer assisted tomography · 2026
- Diagnostically Calibrated AI Image Quality Framework Applied to Prostate Cancer Detection at MRI.Radiology · 2026
- Artificial Intelligence for Prostate Cancer Detection and Screening on MRI in Global Populations: The SCARLET-1 Study.Radiology · 2026