Modeling Liquid-Cooled Data Centers in EnergyPlus
Yun-Dam Ko, Dipashreya A. Sur, Cade Napier, Carlos D. D\'iaz-Mar\'in, Rishee K. Jain
Key points
From the paper's conclusion- By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.
Abstract
As AI workloads accelerate data center transition toward high-density racks with direct-to-chip (DTC) liquid cooling, existing simulation tools remain limited in evaluating whole-building and multi-year efficiency. To bridge this gap, we develop a native EnergyPlus object, ElectricEquipment:ITE:LiquidCooled, that models DTC liquid cooling for chilled-water and warm-water architectures as plant-loop components. It couples facility-water loops, rack-side secondary loops, coolant distribution units, and chip-junction temperatures within a single solver. Validation against an independent Modelica implementation across 21 operating conditions, including two full-year runs compared at one-minute resolution, yields loop-temperature RMSE at or below 0.021 K, well within the 0.1 K acceptance threshold. Our case study demonstrates that warm-water liquid cooling reduces annual PUE from 1.43 to 1.25, eliminates on-site water use, and cuts total facility energy by 37.9% relative to an air-cooled baseline. By embedding liquid-cooling logic into EnergyPlus, our work provides whole-building, long-term energy modeling for high-density AI infrastructure within an open-source framework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI Surge Accelerates the Transition to Liquid Cooling: Rethinking Energy and Water Use in Data Center CoolingarXiv · 2026
- Operational analysis of the cooling system in a direct liquid-cooled data center: a measurement and simulation study on the impact of supply water temperatureApplied Energy · 2025
- Integrated Thermal and Energy Optimization of a Solar-Powered 500 MW AI Data Center in Central North TexasApplied Sciences · 2026
- Holistic energy analysis method for thermal management architectures of data centersInternational Journal of Heat and Mass Transfer · 2026
- Performance evaluation of two-phase direct-to-chip liquid cooling combined with air cooling for data centersCase Studies in Thermal Engineering · 2026
- Energy and carbon savings in data centres through liquid-to-chip cooling with differential temperature controlAdvances in Applied Energy · 2026