Using the Lymphocyte Transformation Test to Diagnose Early Knee Arthroplasty Failures from Metal Hypersensitivity and Multidirectional Instability.
Ibrahim Khalilullah, Suhas Nalla, Ritvik Kakumani, Sashita Subburaj, Vineeth Adari, Gerhard E Maale
Dallas Fort Worth Sarcoma Group, Plano, Texas. · Medical City Plano, Plano, Texas.
Key points
From the paper's conclusion- MH patients demonstrated unusually high complication rates. (Journal of Surgical Orthopaedic Advances 35(3):166-171, 2026).
Abstract
This study aims to determine the etiology of knee arthroplasty failures from multidirectional instability (MDI) and chronic synovial inflammation. The cohort consisted of 304 patients with MDI, which was diagnosed using routine preoperative testing and physical examination. Metal-LTT was performed to diagnose metal hypersensitivity (MH). Five hypoallergenic prostheses were utilized during revision treatment (Groups 1 - 5). The prevalence of MH was 85.52% (260/304). The prosthesis most successful at resolving symptoms of failure was the Titanium and Niobium Nitride-coated constrained hinge with polyethylene augments (94.6% successful resolution of symptoms). Complication rates were excessive across all groups (44.9%), primarily due to loosening (37.7%) and infections (25%). TKA failures from MDI and chronic inflammation may need to be worked up for MH and treated with revision to a coated hypoallergenic prosthesis. MH patients demonstrated unusually high complication rates. (Journal of Surgical Orthopaedic Advances 35(3):166-171, 2026).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Orthopedic implant allergies: a review of current knowledge on metal hypersensitivity and prosthesis failure.EFORT open reviews · 2026
- Metal Hypersensitivity in Total Joint Arthroplasty: Molecular Immunopathogenesis, Diagnostic Controversies, and Prospects for Precision Medicine.International journal of molecular sciences · 2026
- Metal Hypersensitivity Reactions Following Spinal Implants: A Systematic Review.JBJS reviews · 2026
- Metal hypersensitivity in spinal surgery: mechanisms, diagnosis, and management - a narrative review.Annals of medicine and surgery (2012) · 2026
- Revision of failed Rubis II prostheses with a dual-mobility Touch implant.Hand surgery & rehabilitation · 2026
- Outcomes of Rotating Hinge Knee Implants in Revision Total Knee Arthroplasty: Instability as a Potential Risk Factor for Mechanical Failure.The Journal of arthroplasty · 2026