Advancing oxygen-enhanced MRI acquisition and modelling through dynamic ${\Delta}R_{1}$ and ${\Delta}R_2^*$ sensing
Jorge Campos Pazmi\~no, Amiel Beausoleil-Morrison, Nathalie Panov, V\'eronique Fortier, Ives R. Levesque
Key points
From the paper's conclusion- The single-reference acquisition strategy reduces data acquisition requirements while preserving sensitivity to both baseline parameters and dynamic changes.
Abstract
Purpose: To develop a multiparametric mapping framework for quantifying fat- and water-specific longitudinal and effective transverse relaxation rates, as well as changes in these parameters induced by a gas challenge. Theory and Methods: The proposed framework, termed SR-Fat DESPOT (single-reference fat-water separated driven equilibrium single-pulse observation of $T_1$), combines a two-component signal model with a single-reference variable flip angle (SR-VFA) approach. The signal model explicitly incorporates gas challenge-induced changes in relaxation rates. The single-reference acquisition strategy reduces data acquisition requirements while preserving sensitivity to both baseline parameters and dynamic changes. Sequence parameters were optimized using Cramer-Rao lower bound theory. SR-Fat DESPOT was evaluated using a modified open-surce abdominal numerical phantom and in two in vivo experiments: a single participant test-retest experiment and a pilot study with six participants. Results: In the abdominal numerical phantom, SR-Fat DESPOT was accurate for quantification of baseline relaxation rates with a normalized median absolute error (nMedAE) <3% for signal-to-noise ratio (SNR) >30 when comparing ground truth and estimates. SR-Fat DESPOT was also able to accurately recover median changes in relaxation rates, with differences within 0.001 $s^-1$ when compared to ground truth. In vivo, SR-Fat DESPOT measured changes in relaxation rates for spleen, kidneys, liver, and muscle under 100% O2 breathing, consistent with reports in literature. Changes detected in the spleen and kidneys were statistically significant across participants. Conclusion: SR-Fat DESPOT can quantify changes in relaxation rates induced by a gas challenge while reducing data requirements compared to more conventional approaches used in MR-oximetry literature.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Protocol optimization for MRI studies in radiation oncology: III. MRI relaxometryPhysics in Medicine and Biology · 2026
- Quantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank ReconstructionNMR in Biomedicine · 2026
- GRACE ‐ MORE : A Motion‐Resolved Golden‐Angle Radial CEST MRI Technique for Free‐Breathing Abdominal ImagingMagnetic Resonance in Medicine · 2026
- Temporal evolution acquisition based arterial spin labeling (TEA-ASL) for accurate estimation of apparent T2 of perfusion signal in brain.Imaging neuroscience (Cambridge, Mass.) · 2026
- Diffusion broadening of the point spread function in steady-state MRIarXiv · 2026
- Effect of Visualized Respiratory Training on Patient Cooperation and Image Quality in Gadoxetic Acid Disodium‐Enhanced Liver MRI : A Randomized Controlled TrialJournal of Magnetic Resonance Imaging · 2026