Is User Calibration Still Necessary for Continuous Myoelectric Control? A Closed-Loop Comparison of Calibration-Free Controllers
Amir Reza Hariri, Kevin B. Englehart, Erik Scheme
Key points
From the paper's conclusion- This study compared six calibration-free controllers, trained on 306 users of the EMG-EPN-612 dataset and used without any calibration data from the test participant, against three calibrated controllers in a closed-loop Fitts' law target-acquisition task with sixteen participants.
Abstract
The need for user-specific calibration remains an often-cited barrier to widespread adoption of myoelectric control. Cross-user models trained on large multi-user datasets can now recognize gestures from unseen users without calibration, but they have been evaluated almost exclusively offline, leaving open whether calibration is still needed in closed-loop control. This study compared six calibration-free controllers, trained on 306 users of the EMG-EPN-612 dataset and used without any calibration data from the test participant, against three calibrated controllers in a closed-loop Fitts' law target-acquisition task with sixteen participants. The calibrated controllers achieved higher offline balanced accuracy (90.6% against 73.1% for the best controller of each paradigm), but completion rates did not differ significantly between paradigms, and the highest completion rate was achieved by a calibration-free controller. Calibrated controllers moved faster on successful acquisitions, partly because of their individually fitted speed mappings, though not significantly after correction for multiple comparisons. However, every calibration-free controller produced more direct and stable trajectories than every calibrated controller, even after adjusting for cursor speed. Offline accuracy did not predict completion rate across controllers or within participants, and across paradigms higher offline accuracy was associated with poorer trajectory quality in 15 of 16 participants. Without any calibration data from the end user, a model trained across a large population matched calibrated control in completion rate and exceeded it in trajectory quality. The offline accuracy gained through calibration should therefore not be taken as evidence of a closed-loop benefit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Co-adaptive Few-shot Calibration Method for Improving Motor Imagery BCI Performance.IEEE journal of biomedical and health informatics · 2026
- Comparing Temporal Deep Learning Architectures for Discrete Cross-User Myoelectric ControlarXiv · 2026
- Myoelectric Control for Upper-Limb Exoskeletons: A Decoder-Shaper-Controller Framework, Design Guidelines, and Future DirectionsarXiv · 2026
- Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched ControlsarXiv · 2026
- Cross-Subject Generalization and Few-Calibration Learning for Fine Motor Imagery BCIs: Evidence Boundaries, Evaluation Recommendations, and a Research Agenda.Bioengineering (Basel, Switzerland) · 2026
- Real-time reinforcement for human-machine interface controlNeuron · 2026