Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning
J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau, S. Stathakis, V. Gr\'egoire, N. Paragios,
Key points
From the paper's conclusion- We present LaDose, a latent diffusion framework for fully volumetric dose prediction.
Abstract
Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prescription-aware diffusion Transformer for esophageal VMAT dose prediction: a retrospective dual-center validation and target-level analysisBioMedical Engineering OnLine · 2026
- DoseSteer: Steering diffusion-based dose prediction models towards clinical targets via Dual-Response GuidancearXiv · 2026
- Enhanced diffusion model with 3D structural and segmentation priors for lung cancer radiotherapy dose prediction.Physics in medicine and biology · 2026
- RadOncGym: An Agent-Based Framework for Radiotherapy Dose-Mimicking OptimizationarXiv · 2026
- A generalizable 3D dose prediction across heterogeneous cohorts: A framework developed for the 2025 AAPM GDP-HMM challenge.Medical physics · 2026
- End-to-end automated radiotherapy planning using transfer learning to overcome data scarcity.Medical physics · 2026