Bridging cone-beam CT and MRI to stopping power ratio maps: a modality-agnostic Brownian bridge approach to support robust adaptive proton therapy.
Yuhao Yan, Qisheng He, Minglei Kang, Behzad Hejrati, Christian Hyde, Ming Dong, Carri Glide-Hurst
Key points
From the paper's conclusion- A novel modality-agnostic rBBrg model was developed to generate high fidelity, deterministic SPR from CBCT or MRI to support efficient and flexible APT workflow.
Abstract
PURPOSE: Adaptive proton therapy (APT) relies on routine offline CT simulations for updated anatomy. We present a modality-agnostic regularized Brownian bridge (rBBrg) framework to deterministically predict stopping power ratio (SPR) maps from CBCTs or MRIs. METHODS: rBBrg consisted of (1) generation mapping where a Brownian bridge predicted SPR from input and (2) reconstruction mapping where a cGAN reconstructed input from predicted SPR. Class embedding was adopted for modality conditioning. Efficient, deterministic prediction was achieved via one-step sampling. Unimodality rBBrg and ResNet were implemented for comparison. Matched-pair planning CT-CBCT (n=37) and CT-MRI (n=21) from head-and-neck cancer patients were evaluated. A calibration phantom was scanned to establish Hounsfield look-up table for real SPR. Predicted SPR maps were evaluated via mean absolute error (MAE), peak-signal-to-noise ratio and structural similarity against ground truth with demonstration of dosimetric performance. RESULTS: For CBCT-SPR synthesis, most metrics were comparable across models (p>=0.05). Modality-agnostic rBBrg outperformed ResNet in MAEbone (0.059 vs 0.067, difference=11%, p<0.05) and showed lower MAEexternal than ResNet (0.038 vs 0.040, p=0.05). Modality-agnostic and unimodality rBBrg were comparable (p>0.05). Qualitatively, both rBBrg better preserved anatomical fidelity than ResNet. For MRI-SPR synthesis, performance was overall comparable across models (p>0.05). Modality-agnostic rBBrg obtained MAEexternal=0.057. Dose calculation comparisons between real and CBCT-predicted SPR were higher in modality-agnostic rBBrg predictions compared to ResNet with gamma pass rate=98.8%/99.3% vs 94.5%/96.9% at 2 mm/2%, respectively. CONCLUSION: A novel modality-agnostic rBBrg model was developed to generate high fidelity, deterministic SPR from CBCT or MRI to support efficient and flexible APT workflow.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration.ArXiv · 2026
- Enhanced two-stage cascaded network for high-precision stopping power ratio and functional image generation from conventional CT.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A Dosimetric and Biological Comparison of Volumetric Modulated Arc Therapy and Adaptive Aperture Proton Therapy for Hippocampal-Sparing Whole-Brain Radiotherapy.Technology in cancer research & treatment · 2026
- Efficient proton adaptive breast radiotherapy with CBCT-Based synthetic CT.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- 4D Pencil Beam Treatment Plan with Conditional Weight PredictionsarXiv · 2026
- Monte Carlo (TOPAS) characterization of a proton therapy OBI: Automated source parameter optimization and analysis of CBCT acquisition dynamics.Medical physics · 2026