Low-Cost Sensor Calibration for Indoor Air Quality Monitoring: A Dataset, Evaluation Scenarios, and a Lightweight Model
Jinyong Yun, Seokho Ahn, Hyungjin Kim, Sungbok Shin, Young-Duk Seo
Key points
From the paper's conclusion- Low-cost sensors enable scalable indoor air quality monitoring but require calibration because of nonlinear distortions, noise, and temporal drift.
Abstract
Low-cost sensors enable scalable indoor air quality monitoring but require calibration because of nonlinear distortions, noise, and temporal drift. The conventional strict pairwise calibration setting requires a co-located reference sensor at each deployment location and does not account for spatial and temporal heterogeneity. To address these limitations, we introduce a six-month dataset comprising multivariate indoor air-quality measurements from low-cost and reference sensors with contextual metadata collected at five locations. Using this dataset, we define four evaluation scenarios. The reference-efficient and location-transfer scenarios evaluate spatial generalization, whereas the long-term drift and event-conditioned scenarios assess robustness to gradual and abrupt distribution shifts. Based on these scenarios, we derive design requirements and propose a lightweight temporal model that combines input-window compression with residual temporal and feature fusion. Experiments show strong calibration performance across all four scenarios with low edge-inference cost.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A review of machine learning approaches for improving calibration and performance of low-cost air quality sensor networksSensor Review · 2026
- How Accurate Are Low-Cost Air Quality Sensors? A 10-Month Study of Three-Tier Comparison with Three Calibration Methods and Cross-Site Transferability.Sensors (Basel, Switzerland) · 2026
- Enhancing Accuracy of Indoor Air Quality Sensors via Automated Machine Learning CalibrationAtmospheric measurement techniques · 2026
- AQ-MultiCal: An Interactive No-Code Machine Learning Platform for Low-Cost Air Quality Sensor Calibration and Comparative Model AnalysisSensors · 2026
- Data-Dependent Performance of Machine Learning Calibration for Low-Cost Indoor Particle Sensors.Environmental pollution (Barking, Essex : 1987) · 2026
- Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practiceBuilding and Environment · 2026