Data-Dependent Performance of Machine Learning Calibration for Low-Cost Indoor Particle Sensors.
Seongjun Park, Kwangbok Jeong, Donghyun Rim, Jaehong Lee, Jaewook Lee
Department of Architectural Engineering, Dankook University, Yongin-si, Gyeonggi-do 16890, Republic of Korea. Electronic address: psj@dankook.ac.kr. · Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University, 209, Neungdong-ro, Gwangjin-gu, Seoul 05006, Republic of Korea. Electronic address: kbjeong7@sejong.ac.kr.
Key points
From the paper's conclusion- These findings demonstrate that the relative benefit of ML-based calibration depends on both training-data characteristics and the performance metric considered, rather than reflecting universal superiority over linear calibration.
Abstract
Low-cost particle sensors are increasingly used for high-resolution indoor air quality monitoring; however, their reliability is affected by source-dependent variability and measurement uncertainty. Although machine learning (ML) models have been widely applied for sensor calibration, their advantages over conventional linear approaches remain inconsistent, particularly in indoor environments. This study investigates how training-data volume and source heterogeneity influence the relative performance of ML-based and linear calibration for indoor particle monitoring. Controlled experiments were conducted in a full-scale residential testbed under three representative particle-source conditions. Linear regression (LR) and three ML models were evaluated under intra-source, cross-source, and multi-source training scenarios. Incorporating particle number concentrations improves calibration performance, increasing R2 by 0.05-0.10 and reducing normalized errors by up to 25%. Among the nonlinear models, LightGBM shows the strongest overall performance and benefits more from increased training-data volume. When training-data volume is held constant, increasing source heterogeneity generally reduces the normalized errors and prediction bias of LightGBM, although it does not improve R2 or enable LightGBM to outperform LR. With further increases in training-data volume under multi-source conditions, LightGBM provides greater benefits for selected error- and bias-related metrics, whereas LR retains higher R2. These findings demonstrate that the relative benefit of ML-based calibration depends on both training-data characteristics and the performance metric considered, rather than reflecting universal superiority over linear calibration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A review of machine learning approaches for improving calibration and performance of low-cost air quality sensor networksSensor Review · 2026
- Enhancing Accuracy of Indoor Air Quality Sensors via Automated Machine Learning CalibrationAtmospheric measurement techniques · 2026
- Low-Cost Sensor Calibration for Indoor Air Quality Monitoring: A Dataset, Evaluation Scenarios, and a Lightweight ModelarXiv · 2026
- Machine Learning Calibration Transfer for Low-Cost Air Quality Sensors: Distance-Based Uncertainty Quantification in a Hybrid Urban Monitoring NetworkAtmosphere · 2026
- AQ-MultiCal: An Interactive No-Code Machine Learning Platform for Low-Cost Air Quality Sensor Calibration and Comparative Model AnalysisSensors · 2026
- Calibration of Low-Cost Particulate Matter Sensors for Exposure Assessment: A Critical Review.Current environmental health reports · 2026