Reducing Spectral Oscillations for Robust Reference Frequency-Based Ultrasound Attenuation Estimation in Harmonic Imaging.
U-Wai Lok, Jingke Zhang, Chengwu Huang, Tao Wu, Jieyang Jin, Ryan M DeRuiter, Jingyi Yin, Lijie Huang,
Key points
From the paper's conclusion- We propose a transmission scheme combining multiple frequencies and steering angles to mitigate oscillations in the FPDCs.
Abstract
Ultrasound attenuation coefficient estimation (ACE) has emerged as a quantitative imaging biomarker for noninvasive assessment of hepatic steatosis. A system-independent technique based on spectral normalization, known as the reference frequency method (RFM), was previously proposed to estimate ACE without requiring a well-calibrated reference phantom. Furthermore, incorporating harmonic imaging can significantly suppress reverberation signals. In previous clinical study, RFM has achieved high correlation with MRI-PDFF, demonstrating its potential for clinical application. However, a major challenge of RFM is the presence of oscillations in the frequency power-ratio decay curves (FPDCs), which can distort the linear fitting used to estimate the attenuation coefficient and consequently degrade ACE accuracy. These oscillations arise from constructive and destructive interference among backscattered echoes, resulting in oscillatory fluctuations in the measured power spectrum that propagate into the FPDCs. We propose a transmission scheme combining multiple frequencies and steering angles to mitigate oscillations in the FPDCs. Averaging these FPDCs suppresses the interference-induced oscillations while preserving the attenuation-dependent decay trend, thereby improving linearity and the accuracy of ACE results. In in-vitro experiments using calibrated phantoms (0.5 and 0.76 dB/cm/MHz) demonstrated that the proposed method improved FPDC linearity and ACE accuracy, achieving an R2 of 0.99 and attenuation coefficient estimates of 0.51 and 0.77 dB/cm/MHz, versus an R2 of 0.89 and estimates of 0.56 and 0.70 dB/cm/MHz for conventional RFM. The proposed method also demonstrated superior performance in a pilot patient study (n=15), achieving a stronger correlation with MRI-PDFF (R = 0.89 vs. 0.83) while reducing inter-measurement variability, indicating improved robustness and clinical potential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated Volumetric ROI Selection for Ultrasound Attenuation-Based Assessment of Liver Steatosis.IEEE transactions on ultrasonics · 2026
- A 2D autocorrelation-based frequency estimator reflecting spatial tissue distribution to improve Ultrasound H-scan tissue characterization.ArXiv · 2026
- Lens-Aware Differentiable Beamforming for In Vivo Distributed Aberration Correction with Curvilinear Transducers.ArXiv · 2026
- WFUMB-Recommended Versus Manufacturer-Optimized Protocols for Ultrasound-Guided Attenuation Parameter in Hepatic Steatosis Assessment: A Retrospective Single-Vendor Multicenter Study.Journal of clinical medicine · 2026
- Ultrasound Normalized Weighted Cumulative Residual Entropy Imaging: A New Quantitative Ultrasound Method for Characterizing Hepatic Steatosis.Diagnostics (Basel, Switzerland) · 2026
- Strategy to Improve Diagnostic Performance of Hepatic Steatosis Grading Using Ultrasound: Combination of Qualitative and Quantitative Approaches.Medicina (Kaunas, Lithuania) · 2026