Automated Volumetric ROI Selection for Ultrasound Attenuation-Based Assessment of Liver Steatosis.
Zongze Li, Tara Kemper, Qi Zeng, Shahed K Mohammed, Emily H T Pang, Changhong Hu, James Jago, Eric M Yoshida,
Key points
From the paper's conclusion- These findings support the feasibility of an automated post-acquisition volumetric attenuation-imaging pipeline that reduces dependence on manual ROI selection for quantitative liver fat assessment.
Abstract
Quantitative ultrasound (QUS) attenuation imaging is a promising low-cost approach for hepatic steatosis assessment, but current methods remain sensitive to operator-defined region-of-interest (ROI) selection and may not fully exploit volumetric acquisitions. We present an automated multi-plane attenuation-coefficient estimation (ACE) method for matrix-array ultrasound that defines and refines the attenuation ROI through learning-based liver masking, vessel exclusion, axial range detection, model-based Aline rejection, and robust plane aggregation. The method was tuned and tested in phantoms and subsequently evaluated against same-visit MRI proton-density fat fraction (MRI-PDFF) in 35 subjects with 237 volumetric acquisitions. Subject-level ACE was defined as the median across repeated acquisitions, and repeatability was quantified using the within-subject coefficient of variation (CV). Subject-level ACE was associated with MRI-PDFF, yielding Pearson r = 0.8835 (95% CI, 0.8182-0.9349), Spearman ρ = 0.9135 (95% CI, 0.7926-0.9579), and R2 = 0.7806. The mean within-subject CV was 3.24% (95% CI, 2.82-3.67%). AUCs were 0.958 (95% CI, 0.871-1.000) for distinguishing S1+ from S0 at MRI-PDFF ≥ 6% and 0.954 (95% CI, 0.878-1.000) for distinguishing S2+ from S0/S1 at MRI-PDFF ≥ 17%. These findings support the feasibility of an automated post-acquisition volumetric attenuation-imaging pipeline that reduces dependence on manual ROI selection for quantitative liver fat assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reducing Spectral Oscillations for Robust Reference Frequency-Based Ultrasound Attenuation Estimation in Harmonic Imaging.ArXiv · 2026
- Diagnostic Accuracy of Quantitative Ultrasound Liver Fat Estimation with MRI-PDFF as the Reference Standard.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Ultrasound Normalized Weighted Cumulative Residual Entropy Imaging: A New Quantitative Ultrasound Method for Characterizing Hepatic Steatosis.Diagnostics (Basel, Switzerland) · 2026
- Comparison of ultrasound-derived fat fraction and hepatorenal index for quantitative detection of hepatic steatosis: a multicenter MRI-PDFF-referenced study.Frontiers in nutrition · 2026
- AI‐Powered 3D Liver Fat Volumetric Map for Clinical‐Grade Steatosis Assessment From Cross‐Modality MRIAdvanced Intelligent Systems · 2026
- WFUMB-Recommended Versus Manufacturer-Optimized Protocols for Ultrasound-Guided Attenuation Parameter in Hepatic Steatosis Assessment: A Retrospective Single-Vendor Multicenter Study.Journal of clinical medicine · 2026