MRI-Free CT-to-Ultrasound Skull Registration in Transcranial Focused Ultrasound using CMUT based Integrated Therapeutic and Imaging Arrays
Reza Pakdaman Zangabad, Sai Vikas Satyanarayana, Costas D. Arvanitis, F. Levent Degertekin
Key points
From the paper's conclusion- Here, we describe an MRI-free CT-to-ultrasound registration framework using a hybrid hemispherical CMUT tFUS array that combines a sparse therapeutic array with an integrated CMUT US-Cross imaging array.
Abstract
Accurate skull-to-array registration is essential for transcranial focused ultrasound (tFUS) because CT-derived skull models must be aligned with the physical-array coordinate system to support patient-specific aberration correction. Current workflows typically use MRI and/or external tracking to establish this spatial relationship, adding imaging infrastructure and coordinate transformations to the treatment workflow. Here, we describe an MRI-free CT-to-ultrasound registration framework using a hybrid hemispherical CMUT tFUS array that combines a sparse therapeutic array with an integrated CMUT US-Cross imaging array. The therapeutic array provides pulse-echo measurements of skull location, while the US-Cross array provides local high-resolution images of the skull surface. The approach was evaluated using a CT-derived outer cortical skull surface across a 25-pose matrix with 10-mm lateral offsets between the skull and array centers and +/-5 degree angular perturbations. Five randomized radial-noise seeds were applied to therapeutic pulse-echo measurements to model measurement or element-placement errors, yielding 125 pose-seed realizations per noise and active-element setting. US-Cross imaging features were generated using Field II and delay-multiply-and-sum plane-wave compounding. Four registration modes were evaluated: Therapeutic only, US-imaging only, Sequential, and Fused registration. Fused registration yielded the best overall performance, with a median total displacement error of 0.271 mm [0.169-0.420] and a median rotation error of 0.904 degrees [0.432-1.639]. These results support an all-ultrasound-based approach using a hybrid CMUT tFUS array for MRI-free CT-US skull registration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Subwavelength registration of skull-compensating acoustic holograms via nonlinear parametric array feedbackarXiv · 2026
- Experimental Validation of Skull Acoustic Modelling Strategies for Transcranial Focused Ultrasound Simulation: A Cross-Comparison Study.Physics in medicine and biology · 2026
- A Marker-Based Registration Approach for the Fusion of Ultrasound and 3D Surface ScansCurrent Directions in Biomedical Engineering · 2026
- Computational Modeling of the Acoustic Radiation Force and Viscoelastic Displacement for Transcranial Focused Ultrasound NeuromodulationmedRxiv · 2026
- Frequency Compounding Cross-Spectral Matrix Fitting for Passive Cavitation Imaging.IEEE transactions on ultrasonics · 2026
- Deformable CT-US Registration via Anatomy-Aware Implicit Neural RepresentationsarXiv · 2026