A software tool for parametric collimator creation for linac-based preclinical irradiation studies
Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, M. Ramish Ashraf, Lawrie Skinner, Edward Elliot Graves, Billy W. Loo, Stavros Melemenidis
Key points
From the paper's conclusion- We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold, collimator shell, Cerrobend holder, and beam degrader.
Abstract
Designing custom Cerrobend collimators for linac-based preclinical electron irradiation is labor intensive and susceptible to design inconsistencies. We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold, collimator shell, Cerrobend holder, and beam degrader. Two designs were fabricated and characterized: a 4.0 x 1.5 cm$^2$ bilateral lung collimator centered on the central axis and a 1.5 x 1.5 cm$^2$ unilateral lung collimator with a 7.5 mm jig offset, each with a 15 mm thick Cerrobend collimator and a 10 mm PLA degrader. Kilovoltage planar images were used to assess aperture geometry and casting uniformity. Radiochromic film was used to measure full width at half maximum (FWHM) and 80%-20% penumbra under conventional and ultra high dose rate (UHDR) electron delivery on a Varian TrueBeam, and off axis leakage was measured with an ionization chamber at conventional dose rate. The cast Cerrobend apertures deviated by less than 0.2 mm from their specified designs. FWHM values were within 3% of the nominal field dimensions, and penumbra ranged from 0.73 to 1.05 mm under conventional and UHDR delivery. Crossline leakage 2 cm beyond the collimator edge was below 2% for both collimators at conventional dose rate. Parametric collimator generation standardized digital design inputs for the two evaluated rectangular linac-based electron fields. Further work will assess specimen-level dosimetry, additional aperture geometries, and Monte Carlo integration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intracavitary electron radiotherapy with dynamic shielding for rectal cancer: applicator design and dosimetric characterization.Physics in medicine and biology · 2026
- A convergent electron beam approach for small-field irradiation with reduced bremsstrahlung.Physics in medicine and biology · 2026
- Combining proton FLASH and spatially fractionated radiotherapy: experimental and simulation-based dosimetric characterizationPhysics in Medicine and Biology · 2026
- Field of View Optimization in Cone-Beam Computed Tomography for Bilateral Alveolar Clefts Before and After Bone Grafting.The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2026
- Beam data and model validation for Elekta SRS cone collimator in 6MV and 6MVFFF beams.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Collaborative design and additive manufacturing of a patient-specific high-dose-rate surface mold applicator for upper lip plesiotherapy.Journal of contemporary brachytherapy · 2026