A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy.
Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li, Sibo Tian, David S Yu, Xiaofeng Yang,
Key points
From the paper's conclusion- We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours.
Abstract
Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility StudyarXiv · 2026
- Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration.ArXiv · 2026
- 4D Pencil Beam Treatment Plan with Conditional Weight PredictionsarXiv · 2026
- Current status and upcoming developments for online adaptive proton therapy enabling a closed feedback loop for near real-time adaptationFrontiers in Oncology · 2025
- Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive RadiotherapyarXiv · 2026
- A simple and interpretable method to predict head and neck offline adaptation needs based on anatomical changesMedical Physics · 2026