Current status and upcoming developments for online adaptive proton therapy enabling a closed feedback loop for near real-time adaptation
Virginia Gambetta, Kristin Stützer, Christian Richter
Helmholtz-Zentrum Dresden-Rossendorf · German Cancer Research Center
Key points
From the paper's conclusion- Near real-time adaptive PT (NAPT) relying on online in vivo treatment verification can be a potential solution for many tumor entities (e.g., thoraco-abdominal tumors), which would greatly benefit from the conformality of PT, but are presently challenging to treat with proton beams due to the influence of intrafractional variations.
Abstract
Proton therapy (PT) has the potential to deliver conformal doses to the tumor while sparing normal tissue, but is highly susceptible to treatment uncertainties. The occurrence of anatomical changes during PT treatments has a major impact on the delivered dose, often necessitating plan adaptations that are typically performed offline and require a few days before the adapted plan is ready. In order to react promptly to detected anatomical changes, online adaptive proton therapy (OAPT) has been proposed with the goal of adapting the plan while the patient is on the treatment couch. First OAPT workflows for daily plan adaptation that are effective against interfractional anatomical variations have reached clinical application. However, even faster OAPT workflows are needed to cope with faster anatomical changes. Near real-time adaptive PT (NAPT) relying on online in vivo treatment verification can be a potential solution for many tumor entities (e.g., thoraco-abdominal tumors), which would greatly benefit from the conformality of PT, but are presently challenging to treat with proton beams due to the influence of intrafractional variations. In addition, NAPT offers the opportunity to achieve the long-awaited closed PT feedback loop. In this paper we review the required tasks and necessary components in an OAPT workflow for the application of near real-time adaptation, proceeding sequentially from volumetric imaging for online plan adaptation up to online verification during delivery. Available technology and upcoming developments are discussed. Several aspects regarding regulatory approval, cost-benefit related issues and additional beyond-the-loop tasks are also addressed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Phase 1 Study of Online Proton Adaptive RadioTherapY (PARTY).International journal of radiation oncology, biology, physics · 2026
- An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility StudyarXiv · 2026
- Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration.ArXiv · 2026
- Impact of anatomical changes on simulated proton arc therapy and intensity‐modulated proton therapy for lung cancerJournal of Applied Clinical Medical Physics · 2026
- Patient-Specific Dosimetric Impact of Online Adaptive Radiotherapy for Locally Advanced Cervical Cancer.Biomedical physics & engineering express · 2026
- Nominal plan robustness may predict plan degradation in proton therapy for oropharyngeal head‐and‐neck cancerJournal of Applied Clinical Medical Physics · 2026