A deep dictionary network-based foundation model for ultra-low-dose CT denoising
Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu
Key points
From the paper's conclusion- A deep dictionary network (DDN) model was proposed for ultra-low-dose CT denoising, featuring architectural interpretability and dynamic dictionary modules.
- The model was pre-trained on one million multi-organ normal-dose CT images and fine-tuned on ULDCT datasets.
- The proposed method achieves state-of-the-art performance and surpasses competing ULDCT methods across diverse anatomical regions.
Abstract
Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- A deep dictionary network (DDN) model was proposed for ultra-low-dose CT denoising, featuring architectural interpretability and dynamic dictionary modules.
- The model was pre-trained on one million multi-organ normal-dose CT images and fine-tuned on ULDCT datasets.
- The proposed method achieves state-of-the-art performance and surpasses competing ULDCT methods across diverse anatomical regions.
Readers' thoughts
No reader thoughts yet.
Related papers
- FoundDiff: Foundational Diffusion Model for Generalizable Low-Dose CT DenoisingIEEE Transactions on Medical Imaging · 2026
- Low‐dose CT denoising using a diffusion prior via score distillation samplingMedical Physics · 2026
- Enhancing low-dose CT denoising via multi-view knowledge transfer without paired dataFrontiers in Radiology · 2026
- Image-Domain GAN Denoising for Sn100 kVp Ultra-Low-Dose Chest CT: A Retrospective Paired Image-Quality Study.Diagnostics (Basel, Switzerland) · 2026
- Dual-state adaptive unrolled network for structure-preserving low-dose CT image restoration.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026
- Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT DenoisingarXiv · 2026