Dual-state adaptive unrolled network for structure-preserving low-dose CT image restoration.
Xinyuan Zhang, Yimin Zhu, Qingzhe Cui, Jie Song, Shuo Duan, Xing Wei, Xing Wu, Quan Qian,
School of Computer Engineering and Science, Shanghai University, Shanghai, 200444, China. · School of Computer Engineering and Science, Shanghai University, Shanghai, 200444, China; Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, 200444, China; Key Laboratory of Silicate Cultural Relics Conservation, Ministry of Education, Shanghai University, Shanghai, 200444, China; Wuxi Zhongdun Technology Co., Ltd, Wuxi, 214000, China; Materials Genome Institute, Shanghai University, Shanghai, 200444, China. Electronic address: xingwu@shu.edu.cn.
Key points
From the paper's conclusion- We propose DSAUNet, a Dual-State Adaptive Unrolled Network that maintains persistent anatomy- and degradation-oriented latent states across unrolled stages.
Abstract
Low-dose computed tomography (LDCT) reduces radiation exposure but introduces spatially heterogeneous noise and artifacts that can obscure subtle anatomical structures. We address post-reconstruction image-domain LDCT restoration, where degradation suppression and structure preservation impose competing demands on a single restoration trajectory. We propose DSAUNet, a Dual-State Adaptive Unrolled Network that maintains persistent anatomy- and degradation-oriented latent states across unrolled stages. Rather than acting as transient feature branches, the evolving states participate in parameterizing subsequent restoration behavior through a degradation-oriented global policy coordinate for stage-level modulation and state-derived confidence variables for spatially selective regulation. Direction-aware prior modeling and multi-scale state guidance further realize this state-parameterized restoration process. Under the reported protocols, DSAUNet achieves 40.3721 dB PSNR and 0.9642 SSIM on 2DeteCT, exceeding the strongest baseline by 1.6320 dB and 0.0108, and achieves 47.4277 dB PSNR and 0.9846 SSIM under the patient-level five-fold Mayo evaluation, with a 1.0920 dB PSNR gain over the strongest PSNR baseline. On LoDoPaB-CT, it further obtains 38.5501 dB PSNR and 0.9141 SSIM, with the best PSNR, SSIM, and VIF among the compared methods. Controlled raw-state, persistent state-swapping, policy-coordinate, and confidence-map analyses support functionally differentiated state roles and active adaptive regulation. Bidirectional 2DeteCT-Mayo zero-shot experiments reveal direction-dependent transfer behavior, while unified profiling characterizes an accuracy-complexity trade-off. Together, these results support persistent dual-state controlled unrolling as a structured approach to image-domain LDCT restoration within the evaluated settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State RegulationarXiv · 2026
- A multi-scale cross aggregation network for joint denoising and super-resolution of low-dose CT imagesFrontiers in Medicine · 2026
- Non-Contrast-Informed Low-Dose Multi-Phase Contrast-Enhanced CT Reconstruction via Local Optimal Transport.IEEE transactions on image processing : a publication of the IEEE Signal Processing Society · 2026
- Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT DenoisingarXiv · 2026
- DenoMamba: A Fused State-Space Model for Low-Dose CT DenoisingIEEE Journal of Biomedical and Health Informatics · 2025
- CedeDiff: Context-aware and texture-guided diffusion model for low-dose CT denoising.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026