Smartphone-based Measurement of Post-traumatic Elbow Range of Motion: Agreement with Goniometry and Clinical Assessment.
Dror Ronel, Galina Cohen Shapiro, Nadav Rinott, Avi Fishbein, Yaniv Keren
Department of Orthopedics, Rambam Health Care Campus, Haifa, Israel. · Department of Orthopedics, Rambam Health Care Campus, Haifa, Israel, Medical Corps, Surgeon General's Headquarters, Israel Defense Forces, Ramat Gan, Israel, Department of Military Medicine and "Tzameret", Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel, Institute for Research in Military Medicine (IRMM), Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.
Key points
From the paper's conclusion- Smartphone-based elbow ROM measurements were statistically comparable to goniometry and demonstrated superior correlation and accuracy relative to clinical visual assessments. These findings support the integration of smartphone tools in the clinical setting.
Abstract
BACKGROUND: Elbow range of motion (ROM) is commonly assessed during initial evaluation and follow-up. While goniometry is considered the current gold standard, previous studies have raised concerns regarding its user dependence and measurement consistency. OBJECTIVES: To evaluate whether smartphone application-based elbow ROM measurements are comparable to visual estimation and goniometry in patients following elbow trauma. METHODS: We conducted a prospective cohort study of 18 patients with elbow injuries. Demographic and medical data were collected. Maximal flexion-extension active ROM was measured by goniometry, smartphone application, and visual estimation by orthopedic surgeons. Measurements were compared to determine agreement and accuracy among different modalities. RESULTS: Eighteen patients with elbow injuries were included. Inter-rater reliability was good to excellent across all rater groups (intraclass correlation coefficient 0.78-0.93). Using paired t-tests with Bonferroni correction, only one attending surgeon showed a significant underestimation of extension compared to goniometry (16.9° vs. 22.5°, P < 0.05). No significant differences were found for residents, other attendings, or smartphone measurements in either extension or flexion (P > 0.05). Bland-Altman analysis revealed modest mean bias within ± 6° for all methods, although limits of agreement were wide (up to ± 20-30°). Smartphone-based measurements demonstrated significantly higher and less variable Pearson correlation coefficients with goniometry compared to surgeon visual estimations (0.91-0.95 vs. 0.81-0.93, P < 0.05). CONCLUSIONS: Smartphone-based elbow ROM measurements were statistically comparable to goniometry and demonstrated superior correlation and accuracy relative to clinical visual assessments. These findings support the integration of smartphone tools in the clinical setting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Psychometric Properties of a Smartphone Application for Measuring Shoulder Active Range of Motion in Individuals with and without Shoulder Pain and Mobility DeficitsJournal of Pain Research · 2026
- Reliability and concurrent validity of smartphone-based inclinometer applications for sagittal spinal curvature assessment.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- The Reliability and Validity of Active Range of Motion Measurement for Fingers Using Three-Dimensional Motion Analysis.Sensors (Basel, Switzerland) · 2026
- Comparison of hip and knee range of motion measurements using Azure Kinect and a digital goniometer in elite female weightliftersScientific Reports · 2026
- Accuracy of Visual Estimation of Active Shoulder Elevation Among Orthopedic Physicians: An Exploratory Video-Based Study.Cureus · 2026
- Markerless On-Device Detection of Compensatory Movement Patterns in Upper-Limb Rehabilitation Exercises from Monocular RGB Video: A Validation Study in Healthy Adults.Sensors (Basel, Switzerland) · 2026