Sensors (Basel, Switzerland)

Markerless On-Device Detection of Compensatory Movement Patterns in Upper-Limb Rehabilitation Exercises from Monocular RGB Video: A Validation Study in Healthy Adults.

Artem Pavlikov, Vera Petrosyan, Vladislav Agapov, Mikhail Gorodnichev, Danila Lobunko, Dmitry Skvortsov

Faculty of Information Technologies, Moscow Technical University of Communications and Informatics (MTUCI), Aviamotornaya St. 8A, Moscow 111024, Russia. · Federal Center of Brain Research and Neurotechnologies of the Federal Medical Biological Agency (FMBA of Russia), Ostrovityanova St. 1, Bldg. 10, Moscow 117513, Russia.

Key points

From the paper's conclusion
  • We present a markerless pipeline that analyzes monocular RGB video entirely on-device in the browser, so it never leaves the machine.

Abstract

Neurological disorders drive demand for prolonged upper-limb rehabilitation, yet specialist access is uneven and assessment stays subjective. Marker-based and inertial measurement unit (IMU) systems are accurate but costly and impractical at home, while pose estimation pipelines mostly stop at keypoints, and many process video server-side, raising privacy concerns. We present a markerless pipeline that analyzes monocular RGB video entirely on-device in the browser, so it never leaves the machine. From 33 BlazePose keypoints, it derives five geometric metrics designed to limit body-size dependence-incomplete elbow extension, inter-limb asymmetry, shoulder girdle elevation, lateral trunk lean, and head tilt-compared against empirically calibrated, preliminary thresholds; a finite-state machine segments repetitions, and the flags are pooled into an unvalidated, exploratory quality score. Against an IMU reference over the 0-62∘ range that the recordings cover, the image-plane angle showed a mean absolute error of 2.18∘, below the pre-specified 5∘ tolerance, a trajectory-averaged bias within ±2∘, and Lin's concordance correlation coefficient of 0.956; the difference is, however, proportional to the angle-about 4% of the measured value-so the accuracy should not be extrapolated to larger elevations, and because that comparison was made offline, it does not include the timing error of the causal real-time path. On a single seated frontal-plane abduction task, with 18 healthy volunteers simulating the compensations and annotated by two independent clinicians blind to the instructed condition, compensation detection reached a macro-averaged F1 of 0.75 and 0.72 against the individual raters. The five signs differ in maturity: near-expert for trunk lean and head tilt, moderate for incomplete elbow extension and inter-limb asymmetry, and weakest for shoulder elevation, which a single frontal view cannot fully disentangle from the abduction motion. Running at 22-30 frames per second on consumer laptops without relying on a discrete GPU, it offers an accessible, privacy-preserving proof-of-concept foundation for home telerehabilitation; generalization beyond this one exercise and effectiveness on genuine post-stroke compensations remain to be established.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Markerless On-Device Detection of Compensatory Movement Patterns in Upper-Limb Rehabilitation Exercises from Monocular RGB Video: A Validation Study in Healthy Adults — Science Skim