The performance and role of BI-RADS classification in predicting malignancy in non-palpable breast lesions.
N Abu, S K Lai, H Hussin, N H Shamsudin
Department of Pathology, Faculty of Medicine, Universiti Kebangsaan Malaysia, 56000 Cheras, Wilayah Persekutuan Kuala Lumpur, Malaysia. nasihaabu@ukm.edu.my. · Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 Serdang, Selangor Darul Ehsan, Malaysia.
Key points
From the paper's conclusion- BI-RADS 4A notably exhibited a high false-positive rate, possibly due to benign lesions mimicking cancer radiologically and the operator-dependent nature of radiology. Despite these constraints, findings affirm the crucial role of hook wire localisation biopsy and BI-RADS classification in evaluating non-palpable breast lesions.
Abstract
INTRODUCTION: Breast cancer continues to be a substantial global health concern, constituting a substantial proportion of new cancers diagnosed. Breast Imaging Reporting and Data System (BI-RADS) is a standardised instrument that facilitates the appraisal of lesions in mammographic reporting. A hook wire localisation biopsy (HWLB) is frequently employed to diagnose suspicious microcalcifications or non-palpable lesions. The study aims to ascertain the probability of detecting malignancies in non-palpable breast lesions by examining the malignancy rate detected by BI-RADS classification and HWLB results. MATERIALS AND METHODS: This retrospective study utilised data from patients who underwent HWLB at a tertiary hospital from January 2016 to December 2021. RESULTS: Among the 65 patients analysed, 21.5% exhibited malignant lesions, predominantly detected through routine mammogram screening. There was a statistically significant association (p=0.007) between BI-RADS classification and the malignancy status. Using BI-RADS 4A as the threshold ensures 100% sensitivity but leads to a low specificity of 13.73%, Positive Predictive Value (PPV) of 24.1% and Positive Likelihood Ratio (LR+) of 1.2. While increasing the threshold to BI-RADS 4B improves specificity to 80.4%, reducing false positives. This suggests that many BI-RADS 4A cases are actually mostly benign. CONCLUSION: BI-RADS 4A notably exhibited a high false-positive rate, possibly due to benign lesions mimicking cancer radiologically and the operator-dependent nature of radiology. Despite these constraints, findings affirm the crucial role of hook wire localisation biopsy and BI-RADS classification in evaluating non-palpable breast lesions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and internal validation of an interpretable mammography-based model for malignancy risk stratification in BI-RADS 4 breast lesions.Frontiers in oncology · 2026
- Combined morphology and distribution features for risk stratification in pathology-enriched BI-RADS 4A/4B microcalcifications.BMC cancer · 2026
- Radiologically detectable microcalcifications in histopathologically confirmed ductal carcinoma in situ: The impact of cohort composition on reported prevalence.Current problems in diagnostic radiology · 2026
- Defining the Clinical Indication for Real-Time Artificial Intelligence-Assisted Ultrasound in Breast Lesions with Low Suspicion of Malignancy.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Adult BI-RADS Malignancy Estimates Overpredict Cancer Risk in Pediatric Breast Lesions.The American surgeon · 2026
- The underestimated risk of additional ipsilateral BI-RADS 3 lesions identified by preoperative ultrasound in breast cancer patients.Insights into imaging · 2026