Proposal of a consistent value for the mean excitation energy of liquid water using advanced modeling, detailed simulations and precission proton Bragg curves
Pablo de Vera, Isabel Abril, Flávio Matias, Julian M. B. Shorto, Hélio Yoriyaz, Rafael Garcia-Molina
Key points
From the paper's conclusion- Comparisons with available precise depth-dose measurements provide critical insights that help establish the consistent value $I = 79.4$ eV for liquid water, providing robust physical grounds for improving range prediction for treatment planning.
Abstract
Protontherapy precision depends on accurately knowing the stopping power of liquid water, as it is the most abundant component of soft body tissues. Difficulties when working with volatile liquids have led to a long-standing debate regarding the values of the stopping power and the mean excitation energy $I$ of liquid water. The equivalence between the stopping power of liquid water and amorphous ice per unit mass density across all clinically relevant proton energies opens the possibility to obtain a reliable estimation of the $I$-value of liquid water. In this work, we employ two complementary theoretical methodologies to assess the proton stopping power of water. The MELF-GOS (Mermin Energy Loss Function - Generalized Oscillator Strengths) approach, based on the perturbative dielectric formalism, serves as an accurate reference for sufficiently high energies, while the novel non-perturbative TDDFT-Penn (time-dependent density functional theory - Penn) method ensures accuracy for energies even below the stopping maximum. These stopping-power values were incorporated into the simulation code SEICS (Simulation of Energetic Ions and Clusters through Solids) to evaluate proton Bragg curves from $1$ to $230$ MeV. Comparisons with available precise depth-dose measurements provide critical insights that help establish the consistent value $I = 79.4$ eV for liquid water, providing robust physical grounds for improving range prediction for treatment planning.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sensitivity of silicon-to-water dose conversion and Bragg-peak metrics to stopping-power datasets in proton dosimetry.Physics in medicine and biology · 2026
- An enhanced RPA-LDA model for ion stopping power from cold matter to high-energy density plasmas: A unified, open-source frameworkPhysics of Plasmas · 2026
- Platform for high repetition rate proton stopping power measurements in Warm Dense MatterPlasma Physics and Controlled Fusion · 2026
- Estimation of dose and linear energy transfer for multi-spot single-energy proton probing beams using in-beam PET and neural network.Physics in medicine and biology · 2026
- Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework.World journal of radiology · 2026
- Effects of core electrons on electronic stopping power in proton-irradiated lithium nanosheets.Physical chemistry chemical physics : PCCP · 2026