Comparison between the Traditional Landmark Method and the Real-Time Ultrasound Technique to Determine the Correct Depth of Insertion of Central Venous Catheter in Right Jugular Vein in Pediatric Neurosurgical Patients: A Randomized Controlled Trial.
Shagun Paliwal, Brijesh P Singh, Ravi Prakash, Premraj Singh, Vinita Singh
Anaesthesiology, King George's Medical University, Lucknow, IND. · Anaesthesiology and Critical Care, King George's Medical University, Lucknow, IND.
Key points
From the paper's conclusion- Height-based USG guidance offers a more accurate and effective method for paediatric IJV CVC placement, improving first-attempt success and reducing malposition without increasing complications. Despite a modest increase in procedural time, USG should be considered the preferred technique in this population.
Abstract
BACKGROUND: Central venous catheterization (CVC) is essential in paediatric neurosurgical patients for monitoring and therapeutic purposes. However, determining the optimal catheter insertion depth remains a challenge due to anatomical variability and a lack of standardized guidelines. This study aimed to compare the effectiveness of a height-based ultrasound (USG)-guided technique versus the traditional anatomical landmark approach for right internal jugular vein (IJV) catheterization in children. METHODS: In a prospective randomized controlled trial conducted at a tertiary care centre in North India, 126 children aged 4-12 years undergoing elective neurosurgery were randomized into two groups: Group A (landmark technique) and Group B (USG-guided, height-based formula). Outcomes assessed included insertion depth accuracy, number of attempts, insertion time, and complications. RESULTS: The USG group demonstrated significantly greater first-attempt success (85.7% vs. 66.7%; p = 0.037) and more accurate catheter placement (variation from carina: 2.65 ± 2.60 mm vs. 3.93 ± 3.78 mm; p = 0.028). Mean insertion depth was longer in the USG group (8.82 ± 1.86 cm vs. 8.17 ± 1.51 cm; p = 0.036), and insertion time was also higher (19.98 ± 3.89 min vs. 16.06 ± 3.98 min; p < 0.001). Although not statistically significant, complication rates were lower in the USG group. CONCLUSION: Height-based USG guidance offers a more accurate and effective method for paediatric IJV CVC placement, improving first-attempt success and reducing malposition without increasing complications. Despite a modest increase in procedural time, USG should be considered the preferred technique in this population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound-guided versus open surgical central venous access in children: A systematic review.JPEN. Journal of parenteral and enteral nutrition · 2026
- How to perform ultrasound-guided cannulation in adults.Nursing standard (Royal College of Nursing (Great Britain) : 1987) · 2026
- A Comparison Of Internal Jugular Vein (DV) Cannulation By Usg AndAnatomical Landmark Technique In Emergency SettingJAIMC Journal of Allama Iqbal Medical College · 2026
- Effects of ultrasound-guided ipsilateral internal jugular vein compression on catheter malposition during ultrasound-guided right infraclavicular subclavian venous catheterisation: a randomised controlled trial.Anaesthesia · 2026
- Comparison of a Novel Geometric Landmark Method Versus Conventional Palpation Technique for Central Venous Cannulation: A Comparative Observational Study of Two Techniques.Annals of cardiac anaesthesia · 2026
- Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site.Journal of visualized experiments : JoVE · 2026