JAIMC Journal of Allama Iqbal Medical CollegeOpen accessMedicine

A Comparison Of Internal Jugular Vein (DV) Cannulation By Usg AndAnatomical Landmark Technique In Emergency Setting

Muhammad Omer Ajmal, Muhammad Aslam khan, Zuraira Mujahid, Rashid Minhas, Aakif Yousaf, Hafiz Muhammad Amjad

Sahiwal Medical College · Punjab Institute of Neurosciences

Key points

From the paper's conclusion
  • Access time was 164.51 ± 9.14 seconds in LM group and 87.32 ±8.54 seconds in US group.CONCLUSION: This study concluded that ultrasound guided (UG) technique for internal jugular vein cannulation isbetter (less number of attempts and access time) than landmark (LM) technique in Emergency department patients.

Abstract

BACKGROUND & OBJECTIVE: In recent times, using ultrasonography either in pre-insertion or in real time is acceptedas remedy to reduce failure and malposition rate. It has been suggested that ultrasound guidance could improve thesuccess rate, reduce the number of needle passes, and decrease complications. The objective of this study was tocompare the technique for internal jugular vein cannulation by landmark (LM) and ultrasound guided (UG) inEmergency department patients.METHODOLOGY: It was comparative study conducted at the Department of Anesthesiology, Sahiwal Teaching Hospital,nd st Sahiwal from 22 March 2023 to 21 September 2023.A total of 130 patients of ≥18 years of age of either gender posted emergency surgeries were included. Skininflammation or burn at insertion site, altered coagulation profile (platelet count<50,000 per cu mm, INR > 1.5),known bleeding disorders, prior catheterization, subcutaneous emphysema and patients undergoing radiation therapywere excluded. In group A, Ultrasonography-guided (UG) technique was applied. In group B, Anatomical landmark (LM)technique was applied. Standard triple lumen CVC was used for cannulation in all patients. The position of the CVC wasconfirmed by a chest radiograph at the end of the procedure. The real-time USG-guided technique was performed witha single dedicated USG machine and a 6-13 MHz linear probe for the entire duration of the study.RESULTS: In this study, average number of attempts 1.79 ± 0.71 in land mark group (LM) and average number ofattempts 1.32 ± 0.47 in Ultrasound guided group (UG). Access time was 164.51 ± 9.14 seconds in LM group and 87.32 ±8.54 seconds in US group.CONCLUSION: This study concluded that ultrasound guided (UG) technique for internal jugular vein cannulation isbetter (less number of attempts and access time) than landmark (LM) technique in Emergency department patients.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers