Loop-Mediated Isothermal Amplification as an Alternative to Conventional Smear Microscopy in Pulmonary Tuberculosis.
Shivani Sharma, Parakriti Gupta, Anand Singhal, Ivneet Kour, Harpreet Kaur, Varsha Gupta, Lipika Singhal
Microbiology, Government Medical College and Hospital, Sector 32, Chandigarh, IND. · Microbiology, All India Institute of Medical Sciences, Vijaypur, IND.
Key points
From the paper's conclusion- This study demonstrates the feasibility and diagnostic potential of TB-LAMP for detecting PTB in adults. Its sensitivity and specificity underscore its potential role in accurate diagnosis. However, further validation in a larger and more diverse cohort is required to support its integration into routine TB diagnostic algorithms.
Abstract
BACKGROUND: Timely and accurate diagnosis of pulmonary tuberculosis (PTB) is a cornerstone of optimal disease management. Loop-mediated isothermal amplification (LAMP) is a simple yet potentially useful novel diagnostic tool for TB diagnosis that requires minimal resources. This pilot study was conducted to evaluate the diagnostic performance of TB-LAMP in diagnosing PTB in adults. METHODS: A prospective observational study was conducted, enrolling 100 adults with symptoms suggestive of PTB. Sputum samples were collected and subjected to smear microscopy, culture, GeneXpert, and TB-LAMP in parallel. A composite reference standard (CRS) involving clinical, microbiological, and radiological parameters was used for comparison. Data were analyzed using SPSS version 26.0. The sensitivity, specificity, positive predictive value, and negative predictive value of the TB-LAMP assay and other diagnostic tests were calculated. RESULTS: This study demonstrated a sensitivity and specificity of TB-LAMP compared with the CRS of 74.36% and 91.80%, respectively. TB-LAMP helped identify cases that conventional techniques missed, highlighting its potential for early TB detection. CONCLUSION: This study demonstrates the feasibility and diagnostic potential of TB-LAMP for detecting PTB in adults. Its sensitivity and specificity underscore its potential role in accurate diagnosis. However, further validation in a larger and more diverse cohort is required to support its integration into routine TB diagnostic algorithms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of the updated FUJIFILM SILVAMP TB LAM II assay for pulmonary TB among HIV-negative outpatients at a primary-level clinic in rural China.International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases · 2026
- Diagnostic accuracy of TB-LAMP assay on tongue swabs for pulmonary tuberculosis.Microbiology spectrum · 2026
- Transforming Tuberculosis Detection: Rapid Sensitive Isothermal Nucleic Acid Test Identifies Infection and Key Drug-Resistance Mutations in Resource-Limited Settings.ACS sensors · 2026
- Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic studyInfection · 2026
- Diagnostic accuracy of a novel point-of-care tongue swab assay for pulmonary tuberculosis: a multicentre prospective studyClinical Microbiology and Infection · 2025
- Evaluation of Xpert MTB/RIF Ultra performance on bronchoalveolar lavage fluid samples for pulmonary tuberculosis diagnosis.Respiratory research & clinical practice · 2026