Late-Onset Prosthetic Valve Dysfunction Associated With Hypoattenuated Leaflet Thickening Detected After a New Heart Murmur: A Case Report.
Kazuyoshi Takagi, Kosuke Saku, Hiroki Mine, Takanori Kono, Eiki Tayama
Division of Cardiovascular Surgery, Department of Surgery, Kurume University, Kurume, JPN.
Key points
From the paper's conclusion- We report the case of a 79-year-old woman who underwent minimally invasive aortic valve replacement using a Perceval S sutureless bioprosthesis for severe aortic stenosis.
Abstract
Hypoattenuated leaflet thickening (HALT) is increasingly recognized after bioprosthetic aortic valve replacement; however, its clinical significance and optimal detection strategy in routine practice remain uncertain. We report the case of a 79-year-old woman who underwent minimally invasive aortic valve replacement using a Perceval S sutureless bioprosthesis for severe aortic stenosis. Early postoperative transthoracic echocardiography and cardiac computed tomography demonstrated normal prosthetic valve function without evidence of HALT. Oral anticoagulation was discontinued three months after surgery, and the patient remained asymptomatic. At the one-year follow-up visit, a newly detected systolic heart murmur prompted further evaluation despite stable N-terminal pro-B-type natriuretic peptide levels. Echocardiography revealed increased transvalvular gradients and mild-to-moderate transvalvular regurgitation, while cardiac computed tomography demonstrated HALT involving the right and noncoronary cusps. The combination of hemodynamically significant prosthetic valve dysfunction and CT-confirmed HALT was considered consistent with clinically overt bioprosthetic valve thrombosis. Oral anticoagulation was restarted, followed by complete resolution of HALT and improvement in prosthetic valve hemodynamics. This case demonstrates that clinically overt bioprosthetic valve thrombosis associated with HALT may develop in an asymptomatic patient and that a newly detected cardiac murmur may serve as a clinical trigger for further echocardiographic and CT evaluation. Careful routine clinical follow-up may facilitate recognition of hemodynamically relevant prosthetic valve dysfunction and appropriate therapeutic intervention.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thrombus-Induced Prosthetic Valve Dysfunction Demonstrating Hypo-Attenuated Leaflet Thickening: A Case Report.Clinical case reports · 2026
- Impact of Leaflet Modification on the Occurrence of Hypoattenuated Leaflet Thickening After Valve-in-Valve Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions · 2026
- Post-TAVR Neo-Sinus Geometry and Impaired Ventricular Recovery Are Associated with Early Leaflet Thrombosis: First MDCT Insights from Vietnam.Journal of clinical medicine · 2026
- Hypo-attenuated leaflet thickening after surgical aortic valve replacement with INSPIRIS RESILIA valve.General thoracic and cardiovascular surgery · 2026
- Case Report: Serial 4D-CT evolution from focal leaflet thickening to multileaflet HALT after transcatheter aortic valve replacement in a hemodialysis patient.Frontiers in cardiovascular medicine · 2026
- Progressive morphological changes of a bioprosthetic mitral valve on serial chest CT preceding severe haemodynamic deterioration in systemic sclerosis: a case report.European heart journal. Case reports · 2026