Progressive morphological changes of a bioprosthetic mitral valve on serial chest CT preceding severe haemodynamic deterioration in systemic sclerosis: a case report.
Hoa Q Nguyen, Phu D Bui, Reinel Martin Alvarez Plascencia, Anh T Duong, Huy Q Dang
Department of Cardiology, Cardiovascular and Thoracic Center, Vinmec Smart City, Vinmec International Hospital, A2 Tay Mo Street, Hanoi 100000, Vietnam. · Vinmec International Hospital, Hanoi 100000, Vietnam.
Key points
From the paper's conclusion- Progressive morphological changes of a bioprosthetic valve were retrospectively identified on chest CT performed for a non-cardiac indication before severe haemodynamic deterioration was recognized by echocardiography.
Abstract
BACKGROUND: Structural valve deterioration is an important cause of bioprosthetic valve dysfunction. Morphological abnormalities may precede clinically significant haemodynamic deterioration, but recognition of this progression may depend on longitudinal comparison of imaging studies. CASE SUMMARY: A 76-year-old man with a surgical bioprosthetic mitral valve implanted in 2014 was diagnosed with systemic sclerosis-associated interstitial lung disease in 2022 and subsequently underwent serial chest computed tomography (CT). Echocardiography in 2022 and March 2023 demonstrated preserved prosthetic valve haemodynamics. In August 2024, he was admitted with progressive heart failure and severe bioprosthetic mitral stenosis. Retrospective review of serial CT demonstrated progressive leaflet changes, from a relatively thin appearance in 2022 to mild thickening in 2023 and marked diffuse thickening with an apparent fusion-like configuration in May 2024. Transoesophageal echocardiography demonstrated severe leaflet thickening and restriction with a suspected superimposed thrombotic component. Despite therapeutic enoxaparin, recurrent pulmonary oedema prompted redo mitral valve replacement. Operative examination demonstrated diffuse leaflet thickening, rigidity, and commissural fusion, with non-dominant pannus and thin thrombotic material. DISCUSSION: This case illustrates the value of longitudinal comparison of existing imaging studies. Progressive morphological changes of a bioprosthetic valve were retrospectively identified on chest CT performed for a non-cardiac indication before severe haemodynamic deterioration was recognized by echocardiography. This does not support routine CT surveillance; rather, abnormalities encountered on existing extracardiac imaging may provide an additional signal to consider earlier cardiac reassessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Late-Onset Prosthetic Valve Dysfunction Associated With Hypoattenuated Leaflet Thickening Detected After a New Heart Murmur: A Case Report.Cureus · 2026
- Severe Bioprosthetic Mitral Valve Dysfunction: Multimodality Imaging Identifies Structural Valve Degeneration and Guides Valve-in-Valve TMVR.JACC. Case reports · 2026
- Thrombosis, fibrosis and microcalcification in bioprosthetic aortic valvesEuropean Heart Journal · 2026
- Fibrocalcific phenotypes in calcific aortic valve disease: imaging characterization, treatment timing, and efficacy assessment.Frontiers in cardiovascular medicine · 2026
- Thrombus-Induced Prosthetic Valve Dysfunction Demonstrating Hypo-Attenuated Leaflet Thickening: A Case Report.Clinical case reports · 2026
- Quantitative assessment of bioprosthetic heart valve calcification using photon-counting CTEuropean Heart Journal · 2026