Acute Severe Aortic Regurgitation Immediately After Cardiopulmonary Bypass Initiation in a Patient With a Bicuspid Aortic Valve.
Takumi Yamamoto, Keisuke Sumii
Anesthesiology, Saitama Sekishinkai Hospital, Sayama, JPN.
Key points
From the paper's conclusion- An 80-year-old man with a bicuspid aortic valve (Sievers classification type 1: L/R fusion), severe aortic stenosis, mild AR, and an ascending aortic aneurysm underwent elective aortic valve replacement and ascending aortic replacement.
Abstract
Antegrade cardioplegia delivery during cardiopulmonary bypass (CPB) is standard practice in cardiac surgery, but it carries a risk of perfusion failure and acute myocardial distension in the presence of aortic regurgitation (AR). In patients with a bicuspid aortic valve (BAV), acute exacerbation of AR can occur immediately after initiating CPB. An 80-year-old man with a bicuspid aortic valve (Sievers classification type 1: L/R fusion), severe aortic stenosis, mild AR, and an ascending aortic aneurysm underwent elective aortic valve replacement and ascending aortic replacement. Immediately after starting CPB and entering ventricular fibrillation (VF), the patient developed sudden, severe AR (vena contracta: 10 mm). This caused rapid left ventricular (LV) dilation and subsequent dislodgement of the LV vent cannula into the left atrium. Real-time transesophageal echocardiography (TEE) promptly identified both the severe AR and the cannula displacement. Following aortic cross-clamping, antegrade cardioplegia failed due to massive regurgitant volume overload into the LV. Prophylactically placed retrograde cardioplegia via the coronary sinus was immediately initiated, successfully achieving rapid cardiac arrest. The planned surgical procedures were completed successfully without further complications, and the patient was discharged in good condition on postoperative day 11. In this patient, the acute exacerbation of AR was likely driven by two key factors: first, a rapid elevation in the transvalvular pressure gradient following CPB onset and VF; and second, the unmasking of latent coaptation failure, stemming from BAV asymmetry and calcification, due to the loss of myocardial tone during VF. Real-time TEE monitoring and prophylactic placement of a retrograde cardioplegia cannula are critical for rapid diagnosis, troubleshooting, and ensuring effective myocardial protection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Atypical perfusion compromising circulatory arrest during mechanical root replacement and aortic arch replacement with frozen elephant trunk in ACTA2 aortopathy.Journal of surgical case reports · 2026
- Iatrogenic aortic valve injury after redo-mitral valve replacement in an annulus weakened by bioprosthesis explantation: a case reportJournal of Cardiothoracic Surgery · 2026
- Mild eccentric aortic regurgitation in bicuspid aortic valve causing anterior mitral leaflet perforation.Annals of pediatric cardiology · 2026
- Paroxysmal atrioventricular block as an initial presentation of bicuspid aortic valve calcification: a case report.European heart journal. Case reports · 2026
- Intractable Pulmonary Edema After PCI: An Extremely Rare Iatrogenic Mechanical Cause.JACC. Case reports · 2026
- Electrical Storm Triggered by Conus Branch Occlusion During Elective Percutaneous Coronary Intervention in Very Severe Aortic Stenosis: Rescue With Balloon Aortic Valvuloplasty Under Venoarterial Extracorporeal Membrane Oxygenation.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026