From the paper's conclusion
  • We report such a case to highlight practical lessons for prevention and detection rather than a novel mechanism.

Abstract

Background Iatrogenic aortic regurgitation is a well-recognized but probably under-reported complication of mitral valve replacement (MVR). Redo-MVR may increase this risk, because explantation of a long-standing prosthesis can leave an attenuated annulus that requires deeper suture bites. We report such a case to highlight practical lessons for prevention and detection rather than a novel mechanism. Case presentation An 80-year-old woman underwent redo-MVR for severe mitral stenosis 9 years after bioprosthetic MVR. After explantation and debridement, the mitral annulus was markedly fragile, and some sutures may have been placed deeper than usual to secure the prosthesis. Post-bypass transesophageal echocardiography (TEE) focused on the mitral prosthesis and showed no paravalvular leak; the aortic valve was not evaluated in detail. Blood pressure was intentionally kept low after surgery to avoid left ventricular rupture. On postoperative day 1, when blood pressure was raised in preparation for extubation, a wide pulse pressure became apparent, and TEE revealed severe aortic regurgitation with restricted motion of the left coronary cusp. At emergency reoperation, a mitral annular suture had entrapped the attachment of the left coronary cusp, causing marked distortion and a 5-mm perforation. Aortic valve replacement was performed, and the patient was discharged after an uneventful recovery. Conclusions When the mitral annulus is weakened after prosthesis explantation, surgeons should recognize that aortic cusp entrapment can occur despite awareness of this risk, favor annular reinforcement over deeper bites, and verify aortic valve competence before closure. Post-bypass TEE should include the aortic valve, and deliberate postoperative hypotension after MVR may mask iatrogenic aortic regurgitation until blood pressure is raised.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers