PeerJ

Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study.

Dihui Lai, Shaowei Cheng, Haiyang Yu, Jianchun Hao, Xiaodi Huang, Saqila He, Yee Jor Choi, Jia Shen,

Department of Dermatology, Beijing ChuiYangLiu Hospital, Beijing, China. · Department of Dermatology, Ba Lin Zuo Qi People's Hospital, Inner Mongolia, China.

Key points

From the paper's conclusion
  • Earphone raw materials contain potential sensitizers under patch test conditions in allergic individuals, with adhesives and acrylate monomers representing candidate allergens requiring further clinical validation.

Abstract

BACKGROUND: Earphone-related allergic contact dermatitis is increasingly reported, yet the sensitization potential of constituent materials remains poorly characterized. OBJECTIVES: To evaluate the allergenic potential of earphone raw materials in a high-risk allergic population using standardized patch testing. METHODS: This two-stage, multicenter prospective study enrolled 261 adults with allergic histories between November 2022 and April 2024 across four regions in China. Stage I patch tested 52 solid materials (e.g., paint, adhesive, and ear cap films) in 61 subjects; Stage II tested 28 liquid substances in 200 subjects. Reading was performed according to the International Contact Dermatitis Research Group (ICDRG) criteria. RESULTS: In Stage I, 66.67% of participants showed ≥ 1 positive allergic reaction to solid earphone raw materials, with adhesives demonstrating the highest per-patch positive allergic reaction rate (7.03%). The overall per-patch positive allergic reaction rate for solid materials was 5.51% (95% CI [4.74-6.38]), significantly lower than that of the Baseline Standard Series (9.50%; 95% CI [7.90-11.30]; P < 0.0001). In Stage II, 15.52% of participants had at least one positive allergic reaction to liquid earphone raw materials, with hexadecamethylcyclooctasiloxane (D8) at 0.01% concentration showing the highest per-patch positive allergic reaction rate (3.45%). The overall per-patch positive allergic reaction rate for liquid materials was 1.13% (95% CI [0.97-1.31]), significantly lower than that of the Baseline Standard Series (14.94%; 95% CI [13.30-16.71]; P < 0.0001). CONCLUSION: Earphone raw materials contain potential sensitizers under patch test conditions in allergic individuals, with adhesives and acrylate monomers representing candidate allergens requiring further clinical validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Sensitization potential of chemical constituents in earphone materials in high-risk populations: a multicenter patch test study — Science Skim