Visual rigid laryngoscope versus Macintosh laryngoscope using low-dose relaxants in thyroid surgery.
Weihuang Qiu, Tingjie Wang, Lijun Weng, Menglu Shi, Cailing Guo, Binmei Yu, Xianzhong Lin, Bo Lin,
Department of Anesthesiology, Anesthesiology Research Institute, the First Affiliated Hospital, Fujian Medical University, Fuzhou, Fujian, China.
Key points
From the paper's conclusion- For thyroid surgery using a low-dose muscle relaxant protocol to enable IONM, the VRL provides significantly shorter intubation time and better hemodynamic stability at intubation compared with the Macintosh laryngoscope. No significant differences were observed between the two devices in intubation success rate, laryngoscopic view, or intubation-related complications.
Abstract
OBJECTIVE: This study evaluated the safety and efficacy of the Macintosh laryngoscope versus the visual rigid laryngoscope (VRL) for tracheal intubation under a low-dose muscle relaxant protocol in thyroid surgery, to provide clinical evidence for the selection of optimal intubation tools for this setting. METHODS: In this single-center, randomized controlled trial, two experienced anesthesiologists performed tracheal intubation using either the Macintosh laryngoscope (Mac group, n = 47) or VRL (VRL group, n = 45) in patients undergoing elective thyroid surgery with Intraoperative neuromonitoring (IONM). The primary outcome was intubation time. Secondary outcomes included first-attempt intubation success rate, hemodynamic changes during the peri-intubation period, laryngoscopic view graded by the Cormack-Lehane classification, and intubation-related complications. RESULTS: The intubation time was significantly shorter in the VRL group (mean ± SD, 33.27 ± 8.36 s) than in the Mac group (52.19 ± 9.83 s) (P < 0.001). The intubation success rate and heart rates did not differ between groups (P > 0.05). The mean arterial pressure (MAP) at intubation and the amplitude of MAP increase during intubation was lower in Group VRL than in Group Mac (P < 0.005). No statistically significant differences were observed between the two groups in peripheral oxygen saturation (SpO2), Cormack-Lehane classification, or intubation-related complications (P > 0.05). CONCLUSION: For thyroid surgery using a low-dose muscle relaxant protocol to enable IONM, the VRL provides significantly shorter intubation time and better hemodynamic stability at intubation compared with the Macintosh laryngoscope. No significant differences were observed between the two devices in intubation success rate, laryngoscopic view, or intubation-related complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comparative study on the hemodynamic changes between King Vision Videolaryngoscope and Macintosh direct laryngoscope in orotracheal intubation under general anesthesiaAsian Journal of Medical Sciences · 2026
- GlideRite® rigid stylet vs Flex-it® articulated stylet for intubation with videolaryngoscopy in patients with semi-rigid cervical collar: a randomized trial.Brazilian journal of anesthesiology (Elsevier) · 2026
- Comparative study of intravenous clonidine versus fentanyl in attenuating hemodynamic response to laryngoscopy and tracheal intubationAsian Journal of Medical Sciences · 2026
- Comparison of upper limb muscle activity and workload during intubation with the Macintosh direct laryngoscope versus C-MAC® and King Vision® videolaryngoscopes in simulated difficult airway scenarios: a randomized crossover trial.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Clinical comparison of midline versus right-sided video laryngoscope insertion for endotracheal intubation in difficult airways: a randomized controlled trial.Anesthesia and pain medicine · 2026
- Video laryngoscope-guided double-lumen tube tracheal intubation in the left-lateral position for thoracoscopic surgery: an open-label randomized non-inferiority trial.American journal of translational research · 2026