Canadian journal of anaesthesia = Journal canadien d'anesthesie

Comparison of upper limb muscle activity and workload during intubation with the Macintosh direct laryngoscope versus C-MAC® and King Vision® videolaryngoscopes in simulated difficult airway scenarios: a randomized crossover trial.

K Smita Reddy, Anju Gupta, Nishkarsh Gupta, Rashmi R Pattanayak, Prateek Maurya, Vinod Kumar, Sachidanand Jee Bharati, Rakesh Garg,

Department of Anaesthesiology and Critical Care Medicine, AIIMS, Bhubaneswar, India. · Department of Anaesthesia, Pain Medicine, and Critical Care, All India Institute of Medical Sciences (AIIMS), New Delhi, India.

Randomised

Key points

From the paper's conclusion
  • In simulated difficult airways, VL reduced upper limb muscle activity compared with DL. Nevertheless, perceived workload was higher with King Vision VL than with DL, whereas it was lower with C-MAC VL. Among the devices tested, C-MAC VL provided the most favorable ergonomic balance, combining reduced muscle strain, lower perceived workload, and highest first-attempt success rate across all airway scenarios.

Abstract

PURPOSE: Tracheal intubation is a physically and mentally demanding for anesthesiologists because it requires fine motor control, technical precision, rapid decision-making, situational awareness, and error avoidance. While videolaryngoscopes reduce muscle strain in normal airways, their ergonomic impact during difficult airway management remains poorly established. We aimed to compare upper limb muscle activity using dynamic surface electromyography during intubation via direct laryngoscopy (DL) vs videolaryngoscopy (VL) in simulated difficult airway scenarios. METHODS: We conducted a randomized crossover trial involving 35 experienced anesthesiologists who performed tracheal intubation on a high-fidelity manikin with a normal airway, locked jaw, and rigid neck, respectively, using a Macintosh direct laryngoscope, a C-MAC® videolaryngoscope (C blade), and a King Vision® channeled videolaryngoscope. The primary outcome was upper limb muscle activity, measured by surface electromyography. Secondary outcomes included intubation time, force on upper incisors, first-attempt success rate, and perceived workload (National Aeronautics and Space Administration Task Load Index [NASA-TLX] score). RESULTS: Direct laryngoscopy produced significantly higher brachioradialis muscle activity than C-MAC VL in the simulated normal airway (16 vs 13 µV; median difference [MD], 3 µV; 95% confidence interval [CI], 0 to 5; P = 0.04), locked jaw (18 vs 12 µV; MD, 6 µV; 95% CI, 1 to 11; P = 0.02), and rigid neck (16 vs 13 µV; MD, 4 µV; 95% CI, 0 to 9; P = 0.03) scenarios. Direct laryngoscopy was the fastest method but exerted the highest force on the incisors (P < 0.001). King Vision VL was associated with the highest NASA-TLX workload score (P < 0.001 compared with DL), whereas C-MAC VL was least demanding. CONCLUSION: In simulated difficult airways, VL reduced upper limb muscle activity compared with DL. Nevertheless, perceived workload was higher with King Vision VL than with DL, whereas it was lower with C-MAC VL. Among the devices tested, C-MAC VL provided the most favorable ergonomic balance, combining reduced muscle strain, lower perceived workload, and highest first-attempt success rate across all airway scenarios. STUDY REGISTRATION: Clinical Trials Registry of India (CTRI/2021/11/038305); first submitted on 26 November 2021.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers