Assessment of pleural effusion using intracavitary contrast-enhanced ultrasound: a pilot study.
Dachuan Tang, Dan Wang, Zhongyu Li, Bohan Lu, Huiming Yi, Wei Zhang
Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Key points
From the paper's conclusion- Intracavitary CEUS could serve as a reliable, minimally invasive, feasible radiation-free adjunctive technique for quantifying PE volume and differentiating exudative versus transudative PE in patients undergoing thoracentesis. The A+B-based regression model provides high predictive accuracy, while A and B values facilitate effusion classification. This quantitative CEUS workflow may facilitate clinical decision-making, and its utility for serial monitoring requires further verification in large-scale real-world cohorts.
Abstract
OBJECTIVES: To address the limitations of current imaging modalities, the present study aimed to develop and validate a novel intracavitary contrast-enhanced ultrasound (CEUS) approach for the quantitative assessment of pleural effusion (PE) volume and differentiation of exudative PE from transudative PE. METHODS: This cross-sectional diagnostic accuracy study prospectively enrolled 100 patients with PE undergoing US-guided thoracentesis. Intracavitary CEUS was performed using SonoVue microbubbles, and time-intensity curve parameters (A, B, and A+B) were analyzed. PE volume was measured based on the drainage volume, and effusions were classified as exudates or transudates according to Light's criteria. Diagnostic performance was assessed by receiver operating characteristic (ROC) analysis, and a linear regression model was developed to predict PE volume. RESULTS: Exudative PE showed significantly higher baseline intensity parameter B (-35.18 ± 5.17 vs. -41.41 ± 8.64, p < 0.01) and lower peak intensity increment parameter A (1.20 ± 3.27 vs. 6.61 ± 6.10, p < 0.01) compared to transudative PE. The combined parameter A+B (steady-state microbubble concentration index) showed a strong correlation with PE volume (r = 0.912, R 2 = 0.831), yielding the predictive model: V(mL) = -33.345 × (A+B) - 453.071 (intraclass correlation coefficient = 0.950). The ROC analysis revealed moderate diagnostic accuracy for the A value (area under the curve (AUC) = 0.779) and B value (AUC = 0.719) in differentiating exudative PE from transudative PE. CONCLUSION: Intracavitary CEUS could serve as a reliable, minimally invasive, feasible radiation-free adjunctive technique for quantifying PE volume and differentiating exudative versus transudative PE in patients undergoing thoracentesis. The A+B-based regression model provides high predictive accuracy, while A and B values facilitate effusion classification. This quantitative CEUS workflow may facilitate clinical decision-making, and its utility for serial monitoring requires further verification in large-scale real-world cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound assessment of pleural effusion volume in clinical practice: a narrative review.Journal of thoracic disease · 2026
- Exploring pleural effusion characterisation with quantitative thoracic ultrasound imaging: a viewpoint on the investigational role of pixel-based echogenicity analysis in transudate and exudate differentiationBreathe · 2025
- Is Pleural Fluid Presepsin a Reliable Diagnostic Biomarker for Pleural Effusions?Diagnostics (Basel, Switzerland) · 2026
- A-188 Analytical Validation of Albumin Measured in Pericardial FluidClinical Chemistry · 2026
- Ultrasonographic formulas for pleural fluid volume estimation in adults: A scoping review.The ultrasound journal · 2026
- Revisiting Light's criteria: a validated blood-free triple combination matches diagnostic accuracy in over 7000 patientsERJ Open Research · 2026