Overuse and False Restraint in Large Language Model Recommendations for Choosing Wisely Scenarios.
Dean Ariel, Stav Endelman, Guy Laban
Department of Family Medicine, Clalit Health Services, Tel Aviv; and Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv, Israel (D.A.). · Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv; and Division of Dermatology, Rabin Medical Center-Beilinson Hospital, Petach Tikva, Israel (S.E.).
Key points
From the paper's conclusion- The LLMs rarely withheld recommendations for treatment when it was appropriate. Overuse was concentrated in 2 recommendations.
Abstract
BACKGROUND: The Choosing Wisely initiative made recommendations where screening, testing, or treatment may be overused, with caveats around appropriate use. Clinicians are increasingly using large language models (LLMs). OBJECTIVE: To evaluate whether commercial LLMs appropriately call for restraint or action from scenarios based on Choosing Wisely recommendations. DESIGN: Benchmark evaluation. Fifteen Choosing Wisely recommendations were used to develop 225 scenarios (per recommendation, 10 in which restraint was appropriate and 5 in which action was appropriate). Six commercial LLMs (3 runs each) generated 4050 responses to the 225 scenarios, using a prompt from the clinician perspective. SETTING: Production application programming interfaces of OpenAI, Anthropic, and Google from February to March 2026. PARTICIPANTS: No human participants were involved. MEASUREMENTS: Co-primary outcomes were the overuse rate (endorsing action when restraint was appropriate) and the false restraint rate (withholding an appropriate action). RESULTS: The rate of LLM-recommended overuse was 5.4% (95% CI, 0.6% to 12.2%); LLMs did not recommend overuse in 8 of 15 recommendations. Two recommendations accounted for most LLM-recommended overuse: thyroid ultrasound for an incidental subcentimeter nodule (overuse recommended in 42.8% of LLM responses) and routine electrocardiography in low-risk adults (overuse recommended in 28.3% of LLM responses). The LLMs recommended overuse in 0.6% to 3.3% of responses for the remaining 5 recommendations. False restraint was rare (0.6% [CI, 0.1% to 1.2%]), was absent for 11 of 15 recommendations, and was highest for prostate-specific antigen screening (3.3%). LIMITATIONS: Single prompts without follow-up; a benchmark rather than real-world use; responses classified by LLM judge with physician adjudication. Findings may not extend to consumer-facing use. CONCLUSION: The LLMs rarely withheld recommendations for treatment when it was appropriate. Overuse was concentrated in 2 recommendations. PRIMARY FUNDING SOURCE: None.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Blinded expert assessment of action acceptability in synthetic clinical outputs from local large language modelsDiscover Informatics · 2026
- Clinical Large Language Model Evaluation by Expert Review (CLEVER): Framework Development and ValidationJMIR AI · 2025
- Validating LLM judges for automated oversight of patient communicationmedRxiv · 2026
- Clinicians need to review only half of LLM outputs to preserve diagnostic accuracy: the SCOUT randomised crossover trialEuropean Heart Journal · 2026
- Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based VerificationarXiv · 2026
- The Best of Both Worlds: How Combining a Large Language Model and a Rule-Based Algorithm Makes Catheter-Associated Urinary Tract Infection Surveillance More EfficientClinical Infectious Diseases · 2026