The Cardiac Efficiency Index: A Novel Parameter to assess Left Ventricular Diastolic Performance
J. Rajkumar, S. Manjunath, M. Makan, J. Moreno, J. Davis, A. May
Key points
From the paper's conclusion- We convenience sampled 82 patients with recent transthoracic echocardiography.
Abstract
BACKGROUND: Standard echocardiographic metrics of diastolic function assess ventricular relaxation and filling pressures largely independent of systolic performance. OBJECTIVES: To introduce and evaluate the Cardiac Efficiency Index (CEI), a novel echocardiographic parameter integrating mitral inflow kinetics with forward stroke volume to provide a more integrated assessment of diastolic physiology. METHODS: We convenience sampled 82 patients with recent transthoracic echocardiography. CEI was evaluated against American Society of Echocardiography (ASE) diastolic dysfunction (DD) grade and left atrial pressure (LAP; normal or elevated). Binary logistic regression evaluated discrimination of elevated LAP and ASE grade [≥]2. Ordinal logistic regression evaluated increasing ASE grade (0-1, 2, 3). RESULTS: Elevated LAP was present in 33/80 (41.3%) patients with valid assessment while 22/66 (33.3%) patients with valid ASE grading had grade [≥]2 DD. For elevated LAP, CEI yielded an AUROC of 0.954 [95% confidence interval (CI), 0.898-0.993] compared with 0.949 [0.895-0.988] for E/e'. For ASE grade [≥]2 AUROC was 0.941 [0.854-0.994] for CEI and 0.942 [0.868-0.991] for E/e'. Ordinal regression demonstrated comparable discrimination (c-index 0.904 [CEI] vs. 0.912 [E/e']) while CEI had a larger per-SD association with increasing ASE grade (OR 10.45 [4.03-27.08]) than E/e' (OR 7.58 [2.92-19.67]). In the combined model, CEI remained independently associated with increasing ASE grade (OR 6.82 [2.24-20.73]; P<0.001) whereas E/e' did not (OR 1.75 [0.70-4.38]; P=0.23). CONCLUSIONS: CEI provided strong discrimination of elevated LAP and ASE DD grade in this proof-of-concept analysis, supporting further validation against invasive hemodynamics in larger cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left atrial–left ventricular coupling index as a novel diagnostic and prognostic marker in HFpEF: systematic review and meta-analysisEuropean Heart Journal · 2026
- Comparison of the 2016 and 2025 ASE/EACVI Guidelines for assessing diastolic dysfunction in patients with preserved left ventricular ejection fractionEuropean Heart Journal · 2026
- Grading left ventricular diastolic function and filling pressure using artificial intelligence-enabled echocardiographyEuropean Heart Journal · 2026
- Addressing Key Limitations of Diastolic Function Assessment in Mouse Echocardiography by Enabling Robust Retrospective Analysis From a Standard Imaging ViewActa Physiologica · 2026
- AI-aided echocardiographic quantification improves efficiency across operator experience levels: a prospective clinical trialEuropean Heart Journal · 2026
- Artificial Intelligence Applied to Echocardiography for Detection of Heart Failure with Preserved Ejection Fraction and Elevated Filling Pressures: A Diagnostic Test Accuracy Meta-Analysis.Cardiology in review · 2026