Grading left ventricular diastolic function and filling pressure using artificial intelligence-enabled echocardiography
R Loutati, M Fiman, A Am-Shalom, N Rubin, R Kuperstein, E Raanani, E Schwammenthal, R Klempfner,
Key points
From the paper's conclusion- Background Assessment of left ventricular diastolic dysfunction (LVDD) and filling pressure is standard in echocardiography but remains time- and expertise-dependent.
Abstract
Background Assessment of left ventricular diastolic dysfunction (LVDD) and filling pressure is standard in echocardiography but remains time- and expertise-dependent. We evaluated the performance and prognostic significance of an artificial intelligence (AI)-enabled echocardiography for LVDD grading. Methods An AI model was developed to classify four grades of LVDD using only apical four-chamber transthoracic echocardiography (TTE) videos without Doppler imaging acquired between 2012 and 2023. Model performance was assessed against contemporary echocardiographic grading guidelines and invasive measurements, and further evaluated in a prospective point-of-care ultrasound (POCUS) cohort acquired by non-cardiologists (Trial number NCT05455541). Associations between model outputs and mortality and heart failure (HF)-related events were examined. Results The study included 120,649 TTEs from 90,967 patients (mean age 62.9±17.2 years; 43.1% female). In a hold-out test cohort of 23,952 patients, the model achieved an area under the receiver operating characteristic curve (AUC) of 0.888 for detecting both ≥grade 1 and ≥grade 2 LVDD (elevated filling pressure), and 0.960 for grade 3 LVDD. Validation against invasive measurements in 124 patients yielded an AUC of 0.851. Over a median follow-up of 7 years (interquartile range 4.5-10), 35% died and 12.6% experienced HF-related events. Model-predicted elevated filling pressure was independently associated with higher all-cause mortality (hazard ratio 1.55, 95% CI 1.46–1.64, p<0.001) and HF-related events (subdistribution hazard ratio 2.65, 95% CI 2.42–2.89, p<0.001). Consistent diagnostic and prognostic performance was observed in the prospective POCUS cohort. Conclusions AI-enabled echocardiography demonstrated accurate LVDD grading and showed strong associations with clinical outcomes, supporting its potential integration into routine TTE and POCUS practice.Kaplan-Meier survival curvesSpline figure of adverse outcomes
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence-Based Echocardiographic Assessment of Diastolic Dysfunction: A Systematic Review.Echocardiography (Mount Kisco, N.Y.) · 2026
- EchoAgent: a vision–language ai model for guideline-based detection and grading of left ventricular diastolic dysfunction from echocardiographic imagesEuropean Heart Journal · 2026
- Artificial intelligence-enabled electrocardiography for estimating left ventricular filling pressureEuropean Heart Journal · 2026
- Artificial Intelligence‐Enabled ECG for Elevated E/e' on Echocardiography: Hemodynamic Relevance and Prognostic ValueJournal of the American Heart Association · 2026
- Artificial Intelligence Applied to Echocardiography for Detection of Heart Failure with Preserved Ejection Fraction and Elevated Filling Pressures: A Diagnostic Test Accuracy Meta-Analysis.Cardiology in review · 2026
- AI-assisted echocardiographic assessment of left ventricular function in primary care: a prospective implementation studyEuropean Heart Journal · 2026