Anatomy- and Time-Based Post-Processing with CT Perfusion-Derived Time-Vessel Maps to Reduce Incorrect Occlusion Detections in Late-Phase CT Angiography.
Andrés Martínez Mora, Mahsa Mojtahedi, Lucas de Vries, Michael Baumgartner, Yannick Kirchhoff, Maximilian Zenk, Katharina Eckstein, Jessica Kächele,
Department of Medical Image Computing, German Cancer Research Center, 69120 Heidelberg, Germany. · Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Location AMC, 1105 AZ Amsterdam, The Netherlands.
Key points
From the paper's conclusion- Conclusions: Anatomically and temporally informed post-processing reduced incorrect occlusion detections in late-phase CTA without measurable loss of sensitivity, potentially improving robustness against CTA phase changes in external institutions.
Abstract
Background/Objectives: Computer-aided vessel occlusion detection for acute ischemic stroke is typically developed on early-phase CT angiography (CTA). In late-phase CTA, enhanced venous contrast can mimic arterial occlusions and lead to incorrect occlusion detections. To counteract this, we propose a constraint-based post-processing framework that leverages anatomical and temporal vascular information from CT perfusion (CTP) scans. Methods: Vascular anatomy and relative contrast-arrival times were encoded as time-vessel maps. Three complementary constraints worked on these maps to remove incorrect detections based on distance-to-vessel truncation points, contrast-arrival time, and spatial priors. Constraints were fixed on a 32-case late-phase development subset and applied to an external held-out cohort of late-phase CTA (N = 354). To enable application without CTP, an auxiliary CTA-to-time-vessel map generator was designed to estimate maps directly from CTA. Results: In the external cohort, the framework reduced incorrect occlusions per scan from 3.9 (95% CI 3.6-4.2) to 2.1 (95% CI 1.9-2.3), preserving occlusion-level sensitivity at 80% (95% CI 69-91). The patient-level AUROC was 83 for the baseline versus 88 with post-processing. Improvements were also observed in detectors exposed to late-phase CTA, where post-processing reduced incorrect occlusions per scan from 2.8 to 1.9. As only 51 occlusion-positive cases were present in the external cohort, confidence intervals were wide. Consequently, these estimates should be interpreted with caution. Conclusions: Anatomically and temporally informed post-processing reduced incorrect occlusion detections in late-phase CTA without measurable loss of sensitivity, potentially improving robustness against CTA phase changes in external institutions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Generative enhancement of suboptimally opacified cerebral CT angiography for large-vessel occlusion detection: a multireader study.Frontiers in neurology · 2026
- Circle of Willis-Guided Localization for Simultaneous Detection and Classification of Large Vessel Occlusions in Brain CTA.Neuroinformatics · 2026
- Automatic cerebral angiographic perfusion analysismedRxiv · 2026
- Computational Fluid Dynamics Analysis of Contrast Agent Distribution in Acute Large Artery Occlusive Stroke: A Preliminary Proof-of-Concept Study.Revista de neurologia · 2026
- Where Does the Signal Go? Technical Challenges of CT Perfusion in Lacunar and Infratentorial Stroke.Tomography (Ann Arbor, Mich.) · 2026
- TriAIF-RWKV: A Physiology-Guided Spatiotemporal Framework for Robust Arterial Input Function Selection in CT Perfusion Imaging.Entropy (Basel, Switzerland) · 2026