Fit-for-purpose bioanalytical validation of a three-cytokine human PBMC ELISpot panel (IFN-γ, IL-2, IL-4) using CEFX and CPI antigen pools for clinical trial immunomonitoring under a GLP-aligned quality system
K. Li, M. Tang, X. Zhai, H. Cao, P. Guo, N. Zhang, P. Fan, L. Jiang,
Key points
From the paper's conclusion- We performed GLP-aligned, fit-for-purpose validation of three human peripheral blood mononuclear cell (PBMC) ELISpot assays, following Global CRO Council recommendations and FDA, NMPA, and CFDI guidance.
Abstract
Cellular immunity is an increasingly required endpoint in clinical trials of vaccines, immuno-oncology agents, and cell therapies. Multi-cytokine validation packages under a single quality system remain uncommon, and the permissible interval between blood draw and plating or freezing is rarely demonstrated experimentally. We performed GLP-aligned, fit-for-purpose validation of three human peripheral blood mononuclear cell (PBMC) ELISpot assays, following Global CRO Council recommendations and FDA, NMPA, and CFDI guidance. IFN-gamma and IL-2 were stimulated with CEFX Ultra SuperStim Pool (24 h each, plus a validated 48 h IFN-gamma regimen) and IL-4 with CPI Antigen Pool (CTL-CPI-001; 48 h) throughout all validation arms. We characterized limit of detection (LOD), lower limit of quantification (LLOQ), precision, linearity across six plating densities, robustness, pre-analytical PBMC functional stability under five delayed-processing conditions in fresh and cryopreserved arms. All assays met predefined criteria (>=80% of samples with %CV <=40% above LLOQ; R^2 >=0.97); LOD/LLOQ were 13/20 and 37/45 SFU/well for IFN-gamma at 24 h and 48 h, 9/27 for IL-2, and 4/27 for IL-4. Freshly plated PBMC remained within acceptance after up to 8 h plus 24 h of ambient holding, whereas cryopreservation after prolonged delay failed at 8+16 h for IL-2 and IL-4 and at 8+24 h for all three assays, driven by post-thaw viability less than 80%. These data define evidence-based sample-handling windows for multicenter trials. The resulting three-cytokine platform is fit-for-purpose for regulated clinical immunomonitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of the IFN-γ FlowCytoScreen for cytokine-based potency assessment of advanced therapy medicinal products.Frontiers in immunology · 2026
- Development of an effective direct qPCR method for cell therapy product quantification in non-clinical biodistribution studiesRegenerative Therapy · 2026
- Development of a 96-well murine whole blood intracellular cytokine staining (ICS) assay for preclinical tuberculosis immune monitoring.Journal of immunological methods · 2026
- Effects of serum omission during PBMC processing, cryopreservation, and cell culture on clinical ELISpot assay performanceAAPS Open · 2026
- Beyond correlation: Intraclass correlation and bland-altman analysis reveal poor absolute agreement across multiplex cytokine immunoassay platforms.Cytokine · 2026
- Development of an Interferon-γ ELISPOT Assay to Assess Varicella-Zoster Virus-Specific Cell-Mediated Immunity in Children.Infection & chemotherapy · 2026