bioRxivPreprintOpen accessbioinformatics

PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI

A. M. Rulseh, A. Rajan, B. Curl, S. Mohan, J. Vymazal, S. Chawla

Key points

From the paper's conclusion
  • We present PMRIPrep, a Brain Imaging Data Structure (BIDS) App for automated DSC and DCE preprocessing and quantification.

Abstract

While dynamic susceptibility contrast (DSC) MRI measures hemodynamics and dynamic contrast-enhanced (DCE) MRI characterizes vascular permeability, quantitative values from both modalities remain processing-dependent. We present PMRIPrep, a Brain Imaging Data Structure (BIDS) App for automated DSC and DCE preprocessing and quantification. PMRIPrep adapts to available acquisitions and metadata, integrates both modalities within a session, and supports four DSC deconvolution methods and four DCE pharmacokinetic models. In DSC simulations with 4% cerebral blood volume and signal-to-noise ratio 50, pooled median absolute cerebral blood flow error was 13-19% across methods. Median Ktrans bias remained [≤]2% across four model-matched DCE configurations over 0-10% noise. End-to-end OSIPI analyses yielded DCE accuracy and clinical test-retest repeatability scores of 0.85 and 0.85, respectively. Outputs follow BIDS-Derivatives conventions and include machine-readable provenance and visual quality-control reports. PMRIPrep is freely available as a containerized application.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers