Neuro-Oncology

IMG-66 PMRIPrep: automated, reproducible DSC hemodynamic and DCE permeability MRI preprocessing

Aaron Rulseh, Archith Rajan, Brandon Curl, Suyash Mohan, Josef Vymazal, Sanjeev Chawla

Key points

From the paper's conclusion
  • Conclusions PMRIPrep provides standardized, fully automated DSC hemodynamic and DCE permeability processing that achieves robust reproducibility without operator intervention, addressing a key barrier to reliable imaging endpoints in neuro-oncology trials.

Abstract

Background DSC and DCE MRI provide hemodynamic and permeability metrics central to glioma treatment response assessment. However, quantitative values remain sensitive to processing choices. Inter-software variability in normalized rCBV has been reported to average 30%, with test-retest CV as high as 67% depending on postprocessing method. Operator-dependent AIF selection, leakage correction approach, and signal conversion assumptions contribute to this variability. No open-source tool provides integrated DSC and DCE processing with automated quality control and computational reproducibility. Methods We developed PMRIPrep, a containerized BIDS-App that automates DSC hemodynamic and DCE permeability quantification without manual intervention. The pipeline implements fully automatic multi-level AIF detection with population fallback, five DSC deconvolution methods (oSVD default), four DCE pharmacokinetic models with BIC-based automatic selection, leakage correction, and cross-modality integration constraining DCE vp with DSC normalized rCBV. Integrated glioma segmentation provides lesion-level metrics, and facilitates automated NAWM mask generation. Processing was validated against digital reference objects, the OSIPI-DCE challenge dataset, and an external post-treatment GBM cohort (n = 11; 3T). Results On synthetic DROs at clinical noise levels, CBF (oSVD) was recovered within 3–22% for physiological flow ranges, and Ktrans across clinically-relevant permeability generally within 2% (up to 14% for 2CXM at low permeability). On the OSIPI clinical test-retest dataset (8 GBM subjects, 1.5T), fully automated processing achieved within-subject CV of 14.9% for Ktrans, well below the QIBA target of 30%. PMRIPrep’s OSIPI repeatability score (0.89) exceeded all 10 published challenge submissions (range 0.64-0.86), including tools with manual AIF selection. In the external glioma cohort (3T), automatic AIF detection succeeded in all cases, enhancing-tumor median Ktrans ranged 0.024-0.086 min-1 and median normalized rCBV 1.06-2.47; voxelwise comparison against Siemens Tissue4D showed strong agreement (Ktrans r = 0.75, CCC=0.66; normalized rCBV r = 0.88, CCC=0.86). Conclusions PMRIPrep provides standardized, fully automated DSC hemodynamic and DCE permeability processing that achieves robust reproducibility without operator intervention, addressing a key barrier to reliable imaging endpoints in neuro-oncology trials.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

IMG-66 PMRIPrep: automated, reproducible DSC hemodynamic and DCE permeability MRI preprocessing — Science Skim