Plasma Alzheimer's assays agree on level but much less on individual rates of change.
Yi Yang, Vanessa Raymont, James B Rowe, Kellen K Petersen, Ahmet Begde, Rachel Brohier, Rosanna McEwen-Smith, Ivan Koychev,
Key points
From the paper's conclusion- Assays agreed well on cross-sectional levels (intraclass correlation 0.75--0.95 for pTau217, pTau181, GFAP, NfL) but less on individual rates of change (0.44, 95% CI 0.37--0.50, for pTau217).
Abstract
INTRODUCTION: Serial plasma testing is proposed for monitoring Alzheimer's disease and for trials, but its reliability for a person's rate of change is unknown. METHODS: In 393 ADNI participants with three plasma samples over a median 5.0 years, 15 measures of five biomarkers were assayed on aliquots of the same samples, separating shared change from assay-specific variation at each sampling occasion. Results were tested in 1,093 A4/LEARN participants. RESULTS: Assays agreed well on cross-sectional levels (intraclass correlation 0.75-0.95 for pTau217, pTau181, GFAP, NfL) but less on individual rates of change (0.44, 95% CI 0.37-0.50, for pTau217). Assay-specific slope variance was approximately zero, so disagreement was predominantly random. Three-sample single-assay slope reliability was at most 0.40 (0.34-0.46) for pTau217, 0.42 (0.33- 0.51) for pTau181, 0.47 (0.37-0.60) for GFAP, 0.52 (0.40-0.64) for NfL, and 0.10 (0.03-0.20) for Aβ42/40. Two pTau217 measurements had to differ by 65%-131%, depending on the assay, to exceed measurement noise. Detecting 25% slowing of pTau217 change required 924 (598-1,468) to 4,030 (2,091-9,256) participants per arm, or 532 (357-778) to 965 (655-1,431) with averaged measures. In A4/LEARN, single-assay pTau217 reliability was 0.54 (0.46-0.61), and a 7.3-rather than 4.8-year span raised it by 0.10 (0.03-0.22); a fourth sample within it added little. DISCUSSION: With three single-assay samples, much of an individual's measured change is noise. Longer spans, endpoint replication, and assay choice, rather than additional intermediate samples, are needed for reliable serial testing and trials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short-interval variability and test-retest reliability of Alzheimer's disease plasma biomarkers in a clinically heterogenous cohort.Alzheimer's research & therapy · 2026
- Longitudinal trajectories of plasma biomarkers, amyloid-β burden and cognitive decline in Alzheimer's disease.Brain : a journal of neurology · 2026
- Treatment response biomarkers in early Alzheimers disease: longitudinal trajectories, sample size estimates, and the impact of progression variabilitymedRxiv · 2026
- Noise or clearance? Reframing plasma amyloid-β variability in Alzheimer's disease as a measurable clearance signal.Journal of Alzheimer's disease : JAD · 2026
- Longitudinal plasma p-tau217 as a marker for tracking progression and predicting cognitive decline in Alzheimer’s diseaseAlzheimer s Research & Therapy · 2026
- Plasma amyloid-β predicts amyloid-β accumulation in PET A- non-demented participantsJournal of Alzheimer s Disease · 2026