medRxivPreprintOpen accessradiology and imaging

Bootstrapping surgeon labeling campaigns with x0-diffusion: label-efficient vessel segmentation of catheter-based angiograms

N. Ranjan, S. Dev, A. A. Gonzalez

Key points

From the paper's conclusion
  • Objective: Assess which architecture is the most label-efficient for vessel segmentation of catheter-based angiograms, and whether a diffusion model trained with extreme data scarcity could serve as a scaffold for expert annotation.

Abstract

Objective: Assess which architecture is the most label-efficient for vessel segmentation of catheter-based angiograms, and whether a diffusion model trained with extreme data scarcity could serve as a scaffold for expert annotation. Materials and Methods: x0-diffusion, SAM, DeepLabV3, ResNet-UNet, ViT-DPT, and ResNet-ViT hybrid were compared at 16, 32, and 80 labeled images from the 500-image Dr-SAM dataset under 5x5-fold repeated cross-validation, using one-sided paired Wilcoxon signed-rank tests with Holm correction. A vascular surgeon's annotation time, from scratch and when correcting x0-diffusion predictions, was also measured. Results: At 16 training images, x0-diffusion achieved the highest Dice (0.882) and IoU (0.795) of the six models, outperforming every competitor in all 25 paired runs on Dice, by 0.047 over zero-shot SAM and 0.226 over DeepLabV3. The advantage narrowed as labels increased: at 32 images x0-diffusion was not significantly different from the two strongest convolutional models, and at 80 images those models scored marginally higher (0.923 and 0.920 vs. 0.910). Correcting 16-image x0-diffusion predictions on five test angiograms averaged 11.1 surgeon-minutes per image versus 20.6 from scratch. Discussion: The advantage of x0-diffusion is label efficiency, not peak accuracy, with the strongest convolu- tional models needing twice the labels to match it. It rarely fails where zero-shot SAM fails, so at the start of an annotation campaign, correcting its predicted masks could cut surgeon annotation time by an estimated 37 to 45%. Conclusion: With very few labels, x0-parameterized diffusion is the strongest vessel segmenter tested and a candidate scaffold for expert annotation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Bootstrapping surgeon labeling campaigns with x0-diffusion: label-efficient vessel segmentation of catheter-based angiograms — Science Skim