Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior
Tianyuan Wang, Kenan Niu, Stefano Stramigioli
Key points
From the paper's conclusion- These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.
Abstract
Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic ViewsarXiv · 2026
- Latent Interpolation Learning Using Diffusion Models for Cardiac Volume Reconstruction.IEEE transactions on medical imaging · 2026
- Efficient 3D Medical Reconstruction from Sparse Views via 2D Diffusion Models with Curvature Priors.IEEE transactions on image processing : a publication of the IEEE Signal Processing Society · 2026
- One-Step Rectified Flow Reconstruction with Spectral Weighting for Limited-angle Cardiac CT.IEEE transactions on medical imaging · 2026
- CC-GAN: Coronary Artery 3D Reconstruction From Two X-Ray Views With Mamba-Based Topology-Aware Generator and Dual-Domain Discriminator.IEEE journal of biomedical and health informatics · 2026
- Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion ModelarXiv · 2026