Usability, acceptability and feasibility of continuous glucose monitoring among children and adolescents with type 1 diabetes in Kenya
P. Amolo, L. Mungai, A. K. Karume, J. Kibugi, W. Mwende, N. Botella, C. Haldane, Y. Kamau,
Key points
From the paper's conclusion- The System Usability Scale (SUS), a Theoretical Framework of Acceptability-based questionnaire, the Diabetes Distress Scale (DDS), the Glucose Monitoring Satisfaction Survey (GMSS), and a feasibility survey were administered.
Abstract
Introduction Continuous Glucose Monitoring (CGM) is considered standard care in high-income countries. There is, however, limited published evidence on CGM use in low- and middle-income countries. The purpose of this study was to assess the usability, acceptability, and feasibility of CGM use among people living with type 1 diabetes (T1D) and caregivers in a low-resource setting. Research Design and Methods This prospective study conducted at the Kenyatta National Hospital purposively enrolled persons aged 4-25 years who had been on management for T1D for at least six months, and caregivers of those under 18 years. Fourty youth living with T1D used CGM for three months in place of self monitoring of blood glucose (SMBG). The System Usability Scale (SUS), a Theoretical Framework of Acceptability-based questionnaire, the Diabetes Distress Scale (DDS), the Glucose Monitoring Satisfaction Survey (GMSS), and a feasibility survey were administered. Outcomes were summarized descriptively, including means, medians, and frequencies using R statistical software. Results The median SUS score was 98.8 (IQR 92.5-100.0). Acceptability was high, and the median total GMSS score improved from 3.73 to 4.73. Among adolescents and adults, the median overall DDS score reduced from 1.54 to 1.36, with reductions in scores in all domains, except for hypoglycemia distress which increased, and physician distress which remained low. Among caregivers, the median overall DDS score declined from 2.05 (moderate distress) to 1.90 (low distress), with modest reductions in teen management and parent-teen relationship distress and a slight increase in personal distress. Median CGM active wear time was 89%. Conclusion This study comprehensively evaluated CGM across usability, acceptability, and feasibility outcomes, with the findings supporting the integration of CGM into routine diabetes management in low-resource settings. The short follow-up period, however, may not capture changing perceptions or long-term adherence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acceptability, Feasibility, and User Experiences of Continuous Glucose Monitoring in Type 1 Diabetes in Kenya: Perspectives of Adolescents, Young Adults, Caregivers, and Healthcare ProvidersmedRxiv · 2026
- Acceptability, feasibility, quality of life and diabetes distress score outcomes: A pragmatic randomised clinical trial on continuous glucose monitoring for people with type 1 diabetesmedRxiv · 2026
- Glycaemic outcomes of three months of continuous glucose monitoring in children, adolescents and young adults with type 1 diabetes at a Kenyan tertiary hospital: a single-arm prospective study.medRxiv · 2026
- Acceptability of blinded continuous glucose monitoring for people with serious mental illness and type 2 diabetes: findings from an exploratory mixed-methods study.Frontiers in clinical diabetes and healthcare · 2026
- Caregiver Perceptions of Blood Glucose Monitoring in Children and Adolescents Living With Type 1 Diabetes in Kyrgyzstan, Mali, Tanzania, and Peru: Qualitative Study.JMIR diabetes · 2026
- Factors Associated with Utilization and Underutilization of Diabetes Technology in Underrepresented Families Living with Type 1 Diabetes.Diabetes technology & therapeutics · 2026