Acceptability of blinded continuous glucose monitoring for people with serious mental illness and type 2 diabetes: findings from an exploratory mixed-methods study.
Jennifer V E Brown, Ramzi A Ajjan, Najma Siddiqi, Peter A Coventry
School of Medicine and Population Health, University of Sheffield, Sheffield, United Kingdom. · Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds/Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
Key points
From the paper's conclusion- Discussion The use of blinded CGM is both feasible and acceptable for people living with SMI and type 2 diabetes.
Abstract
INTRODUCTION: People with serious mental illness (SMI) experience a disproportionately high prevalence of type 2 diabetes and a reduced life expectancy of 15 to 20 years. While continuous glucose monitoring (CGM) has revolutionised diabetes self-management in the general population, its feasibility and acceptability among individuals living with co-existing SMI remain largely unexamined. METHODS: The study was embedded within the DIAMONDS feasibility study. Community-dwelling adults with SMI and type 2 diabetes (N = 21 eligible) were invited to wear a blinded CGM sensor (FreeStyle LibrePro) for 14 days. Quantitative metrics evaluated uptake, wear duration, data completeness, and adverse events. Semi-structured qualitative interviews (n = 9) explored user experiences. The qualitative analysis used a hybrid human-AI framework approach to map findings onto the Theoretical Framework of Acceptability (TFA) and the Theoretical Domains Framework (TDF), followed by data integration using a convergence coding matrix. RESULTS: Sixteen participants agreed to wear the device (76.2% uptake), achieving a mean wear duration of 11 days. Of the returned sensors with data, 92.8% captured ≥5 days of readings, and no adverse events were reported. Qualitative analysis demonstrated highly positive affective attitudes and a significantly lower perceived burden compared with traditional finger-stick testing, despite minor challenges with sensor adhesion. Cross-framework integration revealed that high acceptability was driven by the device's low-friction physical layout, positive participant beliefs about data consequences, and alignment with a proactive, research-contributing identity. DISCUSSION: The use of blinded CGM is both feasible and acceptable for people living with SMI and type 2 diabetes. These findings offer a robust foundation for developing structured, low-burden, and theory-informed physical health interventions aimed at closing the mortality gap in this underserved population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Supporting continuous glucose monitoring for people with serious mental illness and type 2 diabetes: a co-design study for a structured intervention.Frontiers in health services · 2026
- A Multi-Site Prospective Review of the Use of Continuous Glucose Monitoring in People with HIV and Diabetes.AIDS patient care and STDs · 2026
- Acceptability, feasibility, quality of life and diabetes distress score outcomes: A pragmatic randomised clinical trial on continuous glucose monitoring for people with type 1 diabetesmedRxiv · 2026
- Acceptability, Feasibility, and User Experiences of Continuous Glucose Monitoring in Type 1 Diabetes in Kenya: Perspectives of Adolescents, Young Adults, Caregivers, and Healthcare ProvidersmedRxiv · 2026
- Usability, acceptability and feasibility of continuous glucose monitoring among children and adolescents with type 1 diabetes in KenyamedRxiv · 2026
- Continuous glucose monitoring in older inpatients with type 2 diabetes and cognitive impairment: an open single-arm feasibility study.BMJ open · 2026