medRxiv : the preprint server for health sciencesOpen accessradiology and imaging

Deep Learning Frame Prediction for Abbreviated Low-Dose Dynamic PET Protocols on the PennPET Explorer.

Joran Courtens, Florence M Muller, Elizabeth J Li, Christian Vanhove, Stefaan Vandenberghe, Austin R Pantel, Joel S Karp, Margaret E Daube-Witherspoon

Computational

Key points

From the paper's conclusion
  • This study evaluates a deep learning (DL) framework to enable abbreviated dynamic PET acquisitions, comparing single-time-window (STW, early dynamic data only) and dual-time-window (DTW, early dynamic data plus a late 5-min static frame) protocols with early dynamic scan durations of 5-30 min and dose levels ranging from 360 MBq to 18 MBq.

Abstract

Dynamic positron emission tomography (PET) with long axial field-of-view (LAFOV) scanners enables multi-organ imaging and kinetic quantification beyond static (late-phase) imaging; however, the long times typically required for dynamic acquisitions remain clinically impractical. This study evaluates a deep learning (DL) framework to enable abbreviated dynamic PET acquisitions, comparing single-time-window (STW, early dynamic data only) and dual-time-window (DTW, early dynamic data plus a late 5-min static frame) protocols with early dynamic scan durations of 5-30 min and dose levels ranging from 360 MBq to 18 MBq. Seventeen 60-min dynamic [ 18 F]FDG datasets were first motion-corrected using a staggered FALCON pipeline and then used to train and test a spatiotemporal DL model for autoregressive frame prediction. Performance was assessed across the full quantitative workflow, from DL-predicted frames and time-activity curves to organ-based kinetic modeling and voxel-wise parametric imaging in multiple tissues and two patient cohorts. DTW protocols consistently outperformed STW, better preserving late-phase kinetics. For a 15-min early dynamic scan, adding a late 5-min scan reduced mean absolute K i difference from 23% (STW) to 17% (DTW) in the liver and from 26% to 15% in the thalamus. DTW + DL further reduced errors to ≤10% in the liver, thalamus, and breast lesion, and 16% in muscle. Our recommended protocol, 15-min early dynamic scan plus a 5-min late scan with DL, remained robust to up to a 5-fold dose reduction (∼74 MBq). Overall, these findings support DL-enabled abbreviated, low-dose dynamic LAFOV PET as a clinically feasible approach for accurate kinetic quantification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Deep Learning Frame Prediction for Abbreviated Low-Dose Dynamic PET Protocols on the PennPET Explorer — Science Skim